Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influence
of alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The product is not designed to be used with steam baths!
• If the continuous water heater causes any problems, or you have different water
pressures you must install a water limiter to the cold supply, (ordered separate-
ly,article number 97510000).
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
Shower or spout dripping
English
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
The desired maximum temperature for example max. 42°C can be pre-set thanks to
the safety function.
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
• The check valves must be checked regularly according to EN 806-5 in accord-
• To guarantee the smooth running of the thermostat, it is necessary from time to
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
150±12 mm
cold right - hot left
70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventer in the hose connection and faucet
aerator calcified / fouled
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
- Dirt or sedimentation on valve seat, shut-off unit
damaged
Assembly (see page 4)
Do not use silicone containing acetic acid!
Safety Function (see page 5)
Adjustment (see page 5)
Maintenance (see page 7)
ance with national or regional regulations (at least once a year).
time to turn the thermostat from total hot to total cold.
Dimensions (see page 6)
Flow diagram (see page 6)
Spare parts (see page 10)
Cleaning (see page 9)
Operation (see page 8)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 °C to 60 °C
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Clean or exchange shut-off unit
3