HFS Series Table of Contents Warranty and Contact……………………..……11 Overview……………………………………………….3 Operating Principle and Composition………3 Characteristic…………………………………………3 Specification………………………………………….4 Dimension…………………………………………….5 Wiring Method……………………………………...6 Paddle Standard Table……………………………6 Flow Characteristic Table………………………..7 Precaution for Installation……………………...8 Maintenance……………………………………..9 Precaution for Separation………………………9 Precaution for Inserted External Wire……..9 Precaution for Grounding………………………9 Matters on Safety and Environment………10 Marking…………………..………………………….10...
HFS Series Overview HFS Series is a paddle type flow switch managing of piping systems by sensing of whether fluid is present in the piping line or not to control pump and motor, etc. Operating When the fluid in the pipe line pushes the paddle, the angle of shaft attached to the paddle is...
HFS Series Specification Weather-Proof Model HFS-2T HFS-2S Installation Insertion Inline Type Screw (Std.) or Flange Ambient Temperature -20˚C ~ +60˚C Process Pressure Up to 20kg/cm Process Temperature PBT Housing : Max. 80˚C / AL.C Housing : Max. 120˚C Enclosure Weather-Proof (PBT: IP65 / AL.C : IP66)
HFS Series Dimension Weather-Proof HFS-2T HFS-2S Screw Type Flange Type Screw Type Flange Type Explosion-Proof HFS-2T-Ex HFS-2S-Ex Screw Type Flange Type Screw Type Flange Type Actual product may have a tolerance slightly. * Face to Face Length (mm) Process Connection...
5, 6, 7, 8 6” 6, 7, 8, 9 Please contact to Hitrol in case of non-standard. (Height of the nozzle on the pipe should be provided) Paddle can be used after cutting as per the site condition. ■ HFS-2S...
HFS Series Precaution - Install the product to match the flow direction marked on the product housing. - Be careful to prevent the paddle from coming into contact with the bottom of the pipe. (Information on the height of pipe nozzle should be provided to select a suitable paddle accurately.
HFS Series Maintenance The lifespan of the main parts depends on the user’s environment and can be used optimally through periodic inspection. Therefore, the used should maintain it through periodic inspection at least once a year. When maintenance, checkup should be carried out after power is completely cutting off.
HFS Series Matters on ■ Precaution for use - When fastening the product the piping, make sure to use tools to ensure maximum fastening. Safety and - Do not apply excessive impact to the product. Environment - The user should judge the Ex-Proof area of the relevant product and use the suitable product.
Need help?
Do you have a question about the HFS Series and is the answer not in the manual?
Questions and answers