HITROL HCC-95P Series Instruction Manual

HITROL HCC-95P Series Instruction Manual

Capacitance type level switch
Hide thumbs Also See for HCC-95P Series:

Advertisement

HCC-95P Series
HITROL CO., LTD.
HEAD OFFICE.FACTORY.R&D INSTITUDE
HITROL CO., LTD 141, Palhakgol-gil, Jori-eup
Paju-si, Gyeonggi-do, Korea
TEL. : (+82)-31-950-9700
FAX. : (+82)-31-943-5600
www.hitrol.com
INSTRUCTION MANUAL
CAPACITANCE TYPE LEVEL SWITCH
HCC-95P Series
Doc. no.: HCC95P_IM_Eng_Rev.0
Issue date: 2021. 01
HITROL CO.,LTD.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HCC-95P Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HITROL HCC-95P Series

  • Page 1 HCC-95P Series HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO., LTD 141, Palhakgol-gil, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (+82)-31-950-9700 FAX. : (+82)-31-943-5600 www.hitrol.com INSTRUCTION MANUAL CAPACITANCE TYPE LEVEL SWITCH HCC-95P Series Doc. no.: HCC95P_IM_Eng_Rev.0 Issue date: 2021. 01 HITROL CO.,LTD.
  • Page 2: Table Of Contents

    HCC-95P Series Table of Contents Overview · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 3 APPENDIX APPENDIX U · · · · · · · HCC-95P Setting Guide Characteristics ·...
  • Page 3: Overview

    HCC-95P Series Overview HCC-95P(-Ex) Series is a capacitance type level switch and it detects a level of medium by sensing of capacitance value change by dielectric constant of each medium. ■ Widely used for various type of medium such as solid, powder, and liquid Characteristics ■...
  • Page 4: Specification

    HCC-95P Series Specification Weather-proof Version Model HCC-95P HCC-95PH HCC-95PW HCC-95PWH Probe Type Rod(Flat) Rope Mounting Screw or Flange Ambient temperature -20°C ~ +60°C Process temperature -40°C~+80℃ -40°C~+150℃ -40°C~+80℃ -40°C~+150℃ Process Pressure Vacuum~ 20kg/cm2(300#) Power Source AC 90~240V, 50/60Hz (Std.) / DC +24V (Opt.)
  • Page 5 HCC-95P Series Amplifier Specification Module M-95P Microprocessor 16Bit Microprocessor Stand-by AC 110V @ 3.1W / AC220V @ 7W Active AC 110V @ 3.9W / AC220V @ 7.6W Power Consumption Stand-by DC+24V @ 0.2W Active DC+24V @ 0.96W Oscillation Frequency 1MHz Sensitivity Resolution 0.1pF...
  • Page 6: Dimensions & Technical Data

    HCC-95P Series Dimensions & Technical Data The dimensions on the following pages are indicated in [mm]. [Housing] Material: PBT Material: Aluminum Material: Aluminum [Connection] High Temp. Version High Temp. Version ■ Connection Type -Screw: PT 1” (Std.), NPT 1”, PF 1”, Others...
  • Page 7 HCC-95P Series For Liquids For Solids Rod Probe Rod Probe Fully insulated Rod Probe Rope Probe w/ TEFLON Min. 1,000, Max. 10,000 Total length(L) 100~2,500 300~1,000 100~2,500 ≤2,500 ≤4,500 >4,500 Active Rod Length 100~1,000 150~500 100~1,000 (L-L1) Inactive Rod ~1,500...
  • Page 8: Installation

    HCC-95P Series Installation The capacitance type level switch can be installed in screw (PT, NPT, PF, etc.) and flange (ANSI, JIS, DIN, etc.) as well as tri-clamp and other various locations. Pay attention to the following matters during installation. ■ Side Mounting Installation...
  • Page 9: Precautions For Attachment

    HCC-95P Series Precautions ■ When installing the sensor, avoid shaking or obstacle. for Attachment ■ Do not install in openings that are prone to severe fluid flow, mechanical damage, or chattering. ■ Check the specification of temperature and pressure generated inside the tank.
  • Page 10: Failure Check & Maintenance

    HCC-95P Series The life span of key parts depends on user’s environment and can be used optimally Failure Check through periodic check. Therefore, regular inspection ensures optimal performance of & Maintenance product, so take regular inspection and maintenance at least every year. Inspection of the...
  • Page 11: Precautions For Grounding

    HCC-95P Series Precautions ■ The grounding has an external and an internal grounding. When connecting to an for Grounding external ground, the ground wire shall be 4㎟ (4mmSQ). (The internal grounding shall (Ex-proof) be wiring to the same specification as the connected cable.) Make sure to insert a washer if the terminal lug is removed from ground terminal and then re- connected.
  • Page 12: Marking

    You can request A/S at our website or by contacting our headquarters. ■ Headquarters ․ Factory ․ Laboratory Contact Number ADDRESS: HITROL CO., LTD 141, Palhakgol-gil, Jori-eup, Paju-si, Gyeonggi-do, Korea T E L : 031-950-9700 (Headquarters & A/S) F A X : 031-943-5600 (Headquarters & A/S)
  • Page 13 APPENDIX U HCC-95P Setting Guide Capacitance Type Level Switch Doc. no. : Rev0.0...
  • Page 14 1. M-95P Configuration and Function Configuration Function ■ Autoset SET. ○ Automatic Measurement and Standard of Capacitance on Tank ■ Capacitive Measurement Sensitivity Range Setting RANGE ○ Sensitivity Setting Range: 10pF ~ 150pF ○ Sensitivity Setting Range: BCD Dip Switch ■...
  • Page 15 2. M-95P Setting and Adjustment ■ Initialization Setting Method □ After installing it on the tank, set it to the initial state for quick response. ■ Tuning Setting 1 □ Setting method according to the “Sensitivity Adjustment after Autoset Setting”. Sensitivity Press for 1 sec.
  • Page 16 ■ Tuning Setting 2 □ Setting method according to the “Autoset after Sensitivity Adjustment”. Sensitivity Press for 1 sec. SEN. [Complete] [Adjusting [SET. Push & Pull] Function Method SEN. ■ Set the sensitivity change value of the measuring medium with SEN.
  • Page 17 ■ Adjust Sensitivity □ Measurement sensitivity can be adjusted when installing in a dry contact environment. Sensitivity [Setting Range] [Complete] SEN. [Adjusting Function Method ■ The measurement medium is not in contact. [Non-detection] Dry Contact Environment [Dry Contact Status] ■ It can be adjusted after pressing the tact switch ( SET.) SET.
  • Page 18 □ Measurement sensitivity can be adjusted when installing in a wet contact environment. [Setting Range] SEN. [Complete] [Adjusting Function Method ■ The contact state of the measuring medium. [Detection] Wet Contact Environment [Dry Contact Status] SET.) ■ It can be adjusted after pressing the tact switch ( SET.
  • Page 19 □ Measurement Sensitivity Setting and Fine Adjustment Area...
  • Page 20 ■ Relay Operation Time Adjustment Method □ You can adjust the relay operation time after detecting the medium. [Operating Status According to Relay Delay Time] Function Method ■ Relay Delay Time Time Range: 0.5s, 1s ~ 10s @ Adjustment 0.1s ■...
  • Page 21 ■ Adjust Fail Safe Mode □ You can adjust the contact status to Relay Contact N.C. [Operating Status According to Relay Contact [N.C]] Function Method ■ Relay Contact Out Default Status ■ After detecting the medium, the contact point changes from N.C to N.O. ■...
  • Page 22 3. M-95P UART Monitoring ■ Monitoring Method □ You can only check the state of the adjusted setting values using your PC or Smartphone. □ The execution method is the same using your PC or Smartphone. (Password: 1975) □ Run Screen Component: You can check the sensor measurement status, sensitivity setting value, relay setting, etc.
  • Page 23 ■ Monitoring Method Using Smartphone □ Component: Smartphone(Android OS), OTG, USB Cable(typical USB to Micro USB B), UART ADAPTOR. □ App: Refer to “Serial USB Terminal Install & Setting Guide” [USB Cable] [M-95P Smartphone UART Component] [Enter PW and Fly command] Open App] [Select UART Connection] [Run Screen]...
  • Page 24 APPENDIX H Serial USB Terminal Serial USB Terminal Install & Setting Guide Application : Level Switch / Level Transmitter Doc. no. : Rev0.0 Issued Date : 2020.04.29...
  • Page 25 ■ Installing Serial USB Terminal App □ Search and Install a App that "Serial USB terminal" in the App Store. ■ Serial USB Terminal Setting □ Run The Serial USB Terminal Icon □ Four types of environments must be set up for normal operation of Serial USB Terminal. ▶...
  • Page 26 ■ Serial – Baud rate Setting □ Baud rate : 19200 -> 9600 [Complete] [Select Baud rate] [Setting] [Default] ■ Terminal - Show connection message / Show timestamps Setting □ Show connection message : ON -> OFF □ Show timestamps : ON -> OFF □...
  • Page 27 ■ Receive – Newline Setting □ Newline : CR+LF (Carriage Return + Line Feed) Check [Default] ■ Send - Newline Setting □ Newline : Auto(same as Receive) -> CR [Select Newline] [Default] [Setting] [Complete] Doc. no. : Rev0.0 Issued Date : 2020.04.29...
  • Page 28 ■ Send - Character delay Setting □ Character delay : 0ms -> 5ms [Complete] [Setting] [Default] [Select Character delay] ■ Send – Local echo / Clear input on send Setting □ Local echo : ON -> OFF □ Clear input on send : OFF -> ON [Complete] [Complete] [Select Local echo]...

Table of Contents

Save PDF