SWITCHING OPERATING MODES
To switch operating modes, first lock the navigation buttons by holding both navigation
buttons simultaneously for 3 seconds. Then press any navigation button twice in rapid
succession. Now you can use the navigation buttons to select the desired operating
mode. The selection will be automatically confirmed approximately 10 seconds after the
last button press or by pressing the fire button.
POWER CTRL // WATTS
In this operating mode, you can exclusively operate the device in power control mode
(watts), temperature control is deactivated.
PRESET 1 // SS 316
This operating mode activates the temperature control of the device and is suitable for the
use of stainless-steel wires (V4A / 1.4401 / X5CrNiMo17-12-2 / AISI 316).
PRESET 2 // NICKEL 200
This operating mode activates the temperature control of the device and is suitable for the
use of nickel wires.
PRESET 3 // TITANIUM
This operating mode activates the temperature control of the device and is suitable for the
use of titanium wires.
22 English
LOCKING THE RESISTANCE
To use the temperature control of your PIPELINE BOX, you must lock the resistance [Ω]
before using a new atomizer/coil. If a temperature-controlled operating mode is already
active, and the resistance [Ω] of the newly screwed-on atomizer significantly differs from
the previously locked one, a prompt will appear after a brief press of the fire button, saying
"New Coil? UP YES / DOWN NO." In this situation, you can use the (+) button to lock the
new resistance [Ω] (recommended) or use the (-) button to keep the previously set one.
The locking of the resistance [Ω] can also be done manually. To do this, first activate the
button lock of the device by pressing the fire button 5 times in rapid succession.
Then, hold down the fire button and the (+) button for 2 seconds. The locking of the
resistance [Ω] will be confirmed by a lock symbol next to the displayed resistance
(replacing "Ω"). Repeat the process to release the fixation.
Make sure to lock the resistance only with cold atomizers/coils (room temperature),
otherwise, the displayed temperature [F/C] may significantly differ from the actual
one!
ADJUSTING THE POWER
If the device is in power control mode (watts), use the navigation buttons to increase (+) or
decrease (-) the power [W]. Holding down one of the buttons will increase the adjustment
speed. If the device is in a temperature-controlled operating mode, first activate the button
lock of the device by pressing the fire button 5 times in rapid succession. Then, hold both
navigation buttons simultaneously for 3 seconds to change the power [W] that the device
delivers until the temperature control automatically limits the power. After making the
adjustment, confirm the desired value with the fire button.
English
23
Need help?
Do you have a question about the box and is the answer not in the manual?