COMPONENTS

CONTROL PANEL COMPONENTS

1
1. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
2. Battery Switch: Turns battery ON and OFF. Must be
ON before electric start or remote start.
3. Push-ButtonStart/Stop: Push once to automatically
start the engine. Push again to stop the engine.
4. Eco Mode: Eco mode minimizes fuel consumption
and noise by adjusting the engine RPM to the
minimum required for the current load.
5. 30 Amp AC Circuit Breaker: Receptacle can
supply a maximum of 30 Amps.
6. 20 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
5-20R receptacle to 20 Amps.
7. Battery Charging Port: Used to charge the battery
with the included battery charger.
8. Battery Indicator: Indicates that battery power is
ON. Light will remain illuminated while the unit is ON.
9. Output Ready LED: Illuminates when the generator
is operating normally. Indicates the generator is
producing electrical power at the receptacles.
10. Overload LED: Indicates that the generator is
overloaded.
11. Low Oil LED: Indicates low oil level. When the oil
level in the crankcase falls below the safe operating
limit, the low oil level indicator will illuminate and the
generator will automatically shut off the engine.
10 | English
2
3
4
19
18
17
5
6
7
8
9 10 11 12
16
15
12. Fuel Switch: Used to turn gas valve open or closed.
13. USB Ports: Two-port 5V/2.1A USB outlet. Accepts
Type A USB plugs.
14. Overload Reset: The generator inverter will
automatically switch OFF all AC output to protect
the generator if overloaded or if there is a short
circuit in a connected appliance.
15. LED Data Center: Displays remaining run time (F),
power output in kW (P), fuel level in liters (L), voltage
output (V), and lifetime hours.
16. Parallel
Operation
Westinghouse Inverter Generator can be connected
for additional power output.
17. 120 Volt AC, 20 Amp Duplex NEMA 5-20R
Receptacles: Receptacles can supply a maximum of
20 Amps.
18. Ground Terminal: The ground terminal is used to
externally ground the generator.
19. CO Sensor indicator lights: The CO Sensor
monitors for the accumulation of poisonous carbon
monoxide gas. If increasing levels of CO gas are
detected, the CO Sensor automatically shuts down
the engine.
13
14
Outlets: