Fuse for clamp terminal ES (Xv):
If this fuse is defective, the unit will no longer recognize a clamp that is connected
to terminal ES (Xv), making it impossible to perform a 4-Pole earth measurement
with a clamp or an earth measurement with 2 clamps.
To test this fuse, select the 4-Pole measurement function and connect a test clamp
to terminal ES (Xv). If a clamp symbol does not appear next to the symbol for ter-
minal ES (Xv) in the display, the fuse must be replaced.
Procedure for replacing fuses:
1. Disconnect the unit completely, turn the rotary switch to OFF, and close
2. Loosen the four permanent screws at the bottom of the unit, but do not
3. Open the lid and carefully turn the housing upside-down, making sure the
4. The fuse for terminal H (Z) is accessible at the back of the unit (in the
5. If only the fuse for terminal H (Z) needs to be replaced, jump ahead to step
6. Loosen the two screws on the lid of the battery case and remove the lid.
7. Pull the battery a short way out of the case without overstretching the con-
8. Making sure the battery leads are not overstretched and that the battery
9. The fuse for the clamp terminal ES (Xv) is now accessible on the printed
10. Return the back of the unit to the front panel with the components, taking
56
Find Quality Products Online at:
NOTE: For safety reasons this fuse must always be replaced by an identical
model: 0.63 A F 250V 5x20mm 1.5kA (Cat. #2135.81)
the lid.
remove them.
front panel does not fall out. Then carefully pull the front panel and the unit
all the way out of the housing.
corner near the terminal for the battery charger).
13. To replace the fuse for the clamp terminal ES (Xv), continue on.
nection leads, and loosen the two screws at the bottom of the case. Then
put the battery back into the case.
does not fall out, carefully lift off the back of the unit, turn it over and place
it next to the front panel with the electronic components.
circuit board [in the corner near terminal E (X)]. When replacing the fuse,
avoid touching the circuitry or components.
care not to stretch the battery leads. Carefully lower the back of the unit
and make sure that it is aligned correctly (the four cylindrical holes on the
back must slip over the four mounting pins on the front panel). Also make
sure you do not pinch the battery leads or other wires or components.