Gima CONTEC08A-VET Manual

Gima CONTEC08A-VET Manual

Vet electronic sphygmomanometer
Hide thumbs Also See for CONTEC08A-VET:

Advertisement

Quick Links

PROFESSIONAL MEDICAL PRODUC TS
SFIGMOMANOMETRO ELETTRONICO VETERINARIO
VET ELECTRONIC SPHYGMOMANOMETER
TENSIOMÈTRE VÉTÉRINAIRE ÉLECTRONIQUE
ESFIGMOMANÓMETRO VETERINARIA ELECTRÓNICO
ESFIGMOMANÔMETRO VETERINÁRIO ELETRÔNICO
CONTEC08A-VET (GIMA 80550)
CONTEC MEDICAL SYSTEMS CO., LTD
No.112 Qinhuang West Street, Economic & Technical Development Zone,
Qinhuangdao, Hebei Province, PEOPLE'S REPUBLIC OF CHINA
Made in China
Shanghai International Holding Corp. GmbH (Europe)
Eiffestrasse 80, 20537 Hamburg, Germany
Importato da / Imported by / Importé par / Importado por / Importado por:
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
55°C
95%
1060 hPa
-20°C
0%
700 hPa

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CONTEC08A-VET and is the answer not in the manual?

Questions and answers

Cynthia
March 21, 2025

What does the BPM number stand for?

2 comments:
Mr. Anderson
March 21, 2025

The BPM number for the Gima CONTEC08A-VET refers to the pulse rate, measured in beats per minute (bpm). The device can measure a pulse rate within a range of 30 bpm to 250 bpm, with an error margin of ±2 bpm for measurements between 30 bpm and 100 bpm, and ±2% for measurements between 100 bpm and 250 bpm.

This answer is automatically generated

Cynthia
March 21, 2025

Thank you. Is there a number that shows the mean?

Subscribe to Our Youtube Channel

Summary of Contents for Gima CONTEC08A-VET

  • Page 1 SFIGMOMANOMETRO ELETTRONICO VETERINARIO VET ELECTRONIC SPHYGMOMANOMETER TENSIOMÈTRE VÉTÉRINAIRE ÉLECTRONIQUE ESFIGMOMANÓMETRO VETERINARIA ELECTRÓNICO ESFIGMOMANÔMETRO VETERINÁRIO ELETRÔNICO CONTEC08A-VET (GIMA 80550) CONTEC MEDICAL SYSTEMS CO., LTD No.112 Qinhuang West Street, Economic & Technical Development Zone, Qinhuangdao, Hebei Province, PEOPLE’S REPUBLIC OF CHINA Made in China Shanghai International Holding Corp.
  • Page 2: Chapter 1 Safety Precautions

    ENGLISH FOREWORD product, and strictly follow the operating procedure of the User Ma- Please read the User Manual carefully before using this product. The nual. User Manual which describes the operating procedures should be fol- Fully consider the security requirements during product design, but lowed strictly.
  • Page 3 ENGLISH and goods. contact the biomedical engineer of the hospital or our Customer Service Good damage means the damage of house, property, domestic animal immediately. Do not disassemble, repair and modify the device without and pet. permission. Contraindication Otherwise it cannot be accurately measured. This device can not be used on mobile transport platforms.
  • Page 4: Chapter 2 Main Unit

    ENGLISH When there is breakage of dedicated power adapter plug or wire, please pressure, diastolic pressure, average pressure, pulse rate and record num- do not use it. ber, etc. With 2.8 inch color LCD screen, clear interface, the function of Otherwise it may cause fire or electric shock.
  • Page 5 ENGLISH the production is whole. A. SpO measurement Range:0 %~100 % Error: 70~100 %:±2 %; Below 70 %:unspecified Resolution: 1 % Note: because SpO probe measurements are statisti- cally distributed, only about two-thirds of SpO probe measurements can be expected to fall within ±Arms of the value measu- red by a CO-OXIMETER.
  • Page 6: Chapter 3 External Interfaces

    ENGLISH ◎The cuff is a consumable. Calculate by measuring 6 times a day(3 times each morning and evening), the service life of the cuff is about 2 year. ◎In order to correctly measure blood pressure, please replace the cuff Rear view (using our experimental conditions) ◎If the cuff leaks, please contact our company to buy a new one.
  • Page 7 ENGLISH tions, otherwise it will cause environmental pollution. CHAPTER 6 SETTING THE DATE AND TIME It is necessary to set date and time after power on. 4.2 Usage of power adapter The Electronic Sphygmomanometer can automatically stores measure- 1.Connect the sphygmomanometer and the power adapter. Insert the ment results with date and time.
  • Page 8 ENGLISH 8.2 Technical parameter over-limit prompt When power is about to exhaust and prompt is ON, the prompt will oc- cur. This prompt can not be canceled unless being closed or the power replaced. CHAPTER 9 THE USAGE METHOD OF SPHYGMOMANOMETER 9.1 Accurate Measurement Way It is recommended that you bind the cuff to the forelimbs when the pet pa- tient is lying to the right or left.This treatment can help to make sure that...
  • Page 9 ENGLISH blood flow is smooth. Repeated measurement for a long period of time, limbs rubbing with the cuff may be accompanied by purpura, ischemia and nerve damage. When measurement a animal, it is necessary to frequently check the color, war- mth and sensitivity of the distal of the limb.
  • Page 10: Chapter 10 Memory Function

    ENGLISH 9.3 BP Measurement When some factors affect the measurement results in measurement process, error messages will appear on the screen, you can obviate In order to measure accurately, pay attention to applying the cuff properly. the malfunction and restart a measurement. Select a proper cuff according to different animals, then select proper cuff type(large, middle and small).
  • Page 11 ENGLISH ◎As the measure is taken on the basis of arteriole pulse, substantial pulsa- DATA】option to enter its interface, select the user whose data to be de- leted, after confirming again, all measurement results of the selected user ting blood flow of subject is required. For a subject with weak pulse due to will be deleted.
  • Page 12 ENGLISH ◎The measured value may be normal seemingly for the testee who ◎Please refer to related medical literature for detailed clinical restrictions ◎This device is not used for treatment purpose. has anemia or dysfunctional hemoglobin (such as carboxyhaemoglobin and contraindications, ◎Do not use the SpO (COHb), methaemoglobin (MetHb) and sulfhaemoglobin (SuHb)), but the testee may appear hypoxia, it is recommended to perform further asses-...
  • Page 13: Chapter 13 Error Message

    ENGLISH High-frequency electromagnetic interference such as interference The pulse signal is Correctly connect cuff from electrosurgical apparatus connected to the system. Weak signal too weak or the cuff (refer to Chapter 9) Intravenous dyestuff. is loose. Excessive animal movement. Cuff is blocked or Correctly connect cuff External light.
  • Page 14: Chapter 15 Keys And Symbols

    ENGLISH CHAPTER 15 KEYS AND SYMBOLS No use for a long time, Power off the power of batteries Replace all four Symbol Description suddenly when can be exhausted batteries with new inflating owing to the changed ones. Instruction manual/booklet. temperature Systolic pressure Replace all four Power of batteries can...
  • Page 15 ENGLISH Caution: read instructions (warnings) Serial number carefully USB socket connect SpO probe(This item only suitable Product complies with European Directive for European Union market) Product code Interface for connecting cuff Authorized representative in the European community Socket for power adapter Manufacturer Lot number Keep away from sunlight...
  • Page 16: Chapter 17 Nibp Specification

    ENGLISH If they are very dirty, it is available to dip the Name Electronic Sphygmomanometer soft cloth into water or mild detergent, and Display mode 2.8'' color LCD Display wring out, then use the cloth for cleaning. The device should be inspected and calibrated periodically (or obey The degree of the requirements of the hospital).
  • Page 17 Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment. GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies...