Download Print this page
Gima SP-10 User Manual
Gima SP-10 User Manual

Gima SP-10 User Manual

Pocket spirometer
Hide thumbs Also See for SP-10:

Advertisement

Quick Links

PROFESSIONAL MEDICAL PRODUCTS
SPIROMETRO TASCABILE SP-10
SP-10 POCKET SPIROMETER
SPIROMÈTRE DE POCHE SP-10
ESPIRÓMETRO DE BOLSILLO SP-10
ATTENZIONE: Gli operatori devono leggere e capire
completamente questo manuale prima di utilizzare il prodotto.
ATTENTION: The operators must carefully read and completely
understand the present manual before using the product
GIMA 33536
CONTEC MEDICAL SYSTEMS CO., LTD
No.112 Qinhuang West Street, Economic & Technical
Development Zone, Qinhuangdao, Hebei Province,
PEOPLE'S REPUBLIC OF CHINA
Made in China
SP10
Prolinx GmbH, Brehmstr. 56, 40239
Duesseldorf Germany
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
AVIS: Les opérateurs doivent lire et bien comprendre ce ma-
nuel avant d'utiliser le produit.
ATENCIÓN: Los operadores tienen que leer y entender com-
pletamente este manual antes de utilizar el producto
55°C
-40°C
Manuale d'uso
User manual
Manuel de l'utilisateur
Guía de uso
0123
95%
1060hPa
%
500hPa
0%

Advertisement

loading
Need help?

Need help?

Do you have a question about the SP-10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gima SP-10

  • Page 1 PROFESSIONAL MEDICAL PRODUCTS SPIROMETRO TASCABILE SP-10 SP-10 POCKET SPIROMETER SPIROMÈTRE DE POCHE SP-10 Manuale d’uso User manual ESPIRÓMETRO DE BOLSILLO SP-10 Manuel de l’utilisateur Guía de uso ATTENZIONE: Gli operatori devono leggere e capire AVIS: Les opérateurs doivent lire et bien comprendre ce ma- completamente questo manuale prima di utilizzare il prodotto.
  • Page 2 ENGLISH tory by manufacture can be used with this device. CMS2.782.151(NEW)(CE)ESS/1.2 1.4.01.12.248 2024.01 • This product has been calibrated before leaving factory. Instructions to User Dear users, thank you very much for purchasing the SPIROMETER. 1.2 WARNING Please read the User Manual carefully before using this product. The User ...
  • Page 3 ENGLISH  The display period of data is less than 5 seconds, which is changeable is necessary, disease control and protection shall be strictly followed. according to the end rate. 1.5 EMC DECLARATION:  When data can’t be displayed at all times or other cases happened ...
  • Page 4 ENGLISH 2.3 ENVIRONMENT REQUIREMENTS ‹ Rechargeable lithium battery and with charging tips. Storage Environment: ‹ Battery power display. Temperature: -40℃~+55℃ ‹ 4.2 Main Parameters Relative humidity: ≤95% ‹ Volume Range: 10L Atmospheric pressure: 500hPa~1060hPa ‹ Flow range: 0 L/s~16 L/s Operating Environment: Temperature: +10℃~+40℃...
  • Page 5 ENGLISH with the triangular shape on the shell, gently insert it to the bottom, counterclockwise rotate to lock it 2) Turbine disassembly: clockwise rotate the turbine, gently pull it out 3) Mouthpiece assembly: insert the mouthpiece into the turbine port directly 5.3 ACCESSORIES 1) A User Manual 2) A USB data line...
  • Page 6 ENGLISH under “Date management”. “Number” is the case number displayed at present. For example, if you c. Other parameter interface: display four parameters except the main are the 36th testee, the “Number” will be 36. Case number can increase parameter, as shown in Fig.5. automatically, no need to set manually.
  • Page 7 ENGLISH 6.Exit (2) Trend curve Under (Personal information) interface, select “Exit” to return to (Menu) Under (Data management) interface, select “Trend Curve” to enter (Trend interface. curve selection) interface as shown in Fig.15. Select the determinant pa- rameter, then press “Confirm” key to enter (Trend curve display) as shown in Fig.15.
  • Page 8 ENGLISH decide the denote value, after that, it will automatically return to (Data as shown in Fig.21. Select “Minute” to enter (Minute setting) interface, management) interface. as shown in Fig.22. Press “Up” or “Down” key to change the value (long pressing is available), then press “Confirm”...
  • Page 9 ENGLISH ment completed, it will return to (Settings) interface; if calibrated before Note: If there is no operation within 1 minute, the device will power off measurement completed, it will return to (Testing) interface.). automatically. If the device displays “Error!Please repeat”, it indicates something wrong e.
  • Page 10 ENGLISH Manual (7.1). 2) Please recharge the battery when the screen shows low-power (the battery power is 3) Recharge the battery soon after the over-discharge. The device should be recharged every six months when it is not regular used. It can ex- tend the battery life following this guidance.
  • Page 11 ENGLISH The device is set to automatic power off when there is no Normal. Humidity limit The display disappears operation in one minute. suddenly. The battery is drained away or Please charge the battery. Temperature limit almost drained away. The battery is not full charged. Please recharge the battery. The device can not be Fragile, handle with care used for full time after...
  • Page 12 ENGLISH Guidance and manufacturer’s declaration -electromagnetic emissions and Immunity. Imported by Table 1 Chapter 10 Parameter Introduction Guidance and manufacturer’s declaration – electromagnetic emission MEASURED PARAMETERS Emission test Compliance RF emissions Parameter Description Unit Group 1 CISPR 11 Forced vital capacity RF emission Class B CISPR 11...
  • Page 13 TETRA 800, 18 Hz iDEN 820, CDMA 850, GIMA WARRANTY TERMS LTE Band 5 The Gima 12-month standard B2B warranty applies 1720 1700 GSM 1800; Pulse Disposal: The product must not be disposed of along with other domestic waste. –1990 CDMA 1900;...

This manual is also suitable for:

33536