9. Maintenance
9.1 Safety
To avoid damage to the machine or life-threatening injuries during maintenance of the TEBI 3.0, the following
points must be strictly observed:
•
Turn off the TEBI 3.0 using the On/Off switch and unplug the power cord.
•
Maintenance work should only be performed by authorized personnel with adherence to safety regulations.
•
Use only spare parts listed in our spare parts list.
•
Repairs should only be carried out by the service personnel of esmatec GmbH (Service address as mentioned
in Chapter 1).
•
If specified, use the prescribed special tools (included in the delivery) during maintenance.
•
Always read the safety instructions in Chapter 1.
9.2 Maintenance Schedule
Activity
Clean casing
Before each startup
Replace milling cutter
9.3 Changing the cutter
•
Turn off the TEBI 3.0 using the On/Off switch (1).
EN
Maintenance interval
Weekly
Check safety devices
Poor or unclean chamfer
14
Actions to be performed
Clean the casing or covers with a
neutral cleaning agent.
Verify that the safety devices are
fully applied, secured, and
undamaged.
Follow the procedure for replacing
the milling cutter as described
in the subsequent Chapter 9.3.