LED

This section describes the LED panel. LED indicator includes ALARM, COM,
BACKUP, GRID, BAT, PV indicators.
The table below explains the status and description of all indicators.
LED Indicator
PV
BAT
GRID
COM
BACKUP
ALARM
ALARM
COM
BACKUP
Status Description
On
PV input is normal.
Blink
PV input is abnormal.
Off
PV is unavailable.
On
Battery is available or battery is charging.
Battery is discharging (light on 2S and off 2S).
Blink
Battery is abnormal (light on 1S and off 1S).
Off
Battery is unavailable.
On
GRID is available and normal.
Blink
GRID is abnormal.
Off
GRID is unavailable.
Blink
Data are communicating.
Off
No data transmission.
On
BACKUP power is available.
Blink
BACKUP output is abnormal.
Off
BACKUP power is unavailable.
On
Fault has occurred and inverter shuts down.
Blink
Alarm has occurred but inverter doesn't shut down.
Off
No fault.