Ducar D8600i Operator's Manual

Ducar D8600i Operator's Manual

Inverter generator

Advertisement

Quick Links

INVERTER GENERATOR
OPERATOR'S MANUAL
ORIGINAL INSTRUCTIONS
The picture is only for your reference
MODEL:
D8600i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D8600i and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ducar D8600i

  • Page 1 MODEL: INVERTER GENERATOR D8600i OPERATOR'S MANUAL ORIGINAL INSTRUCTIONS The picture is only for your reference...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction ....................................3 Safety Rules .....................................4 Safety Symbols ................................4 Safety Instructions ...............................4 Features ....................................8 Control Panel Functions .................................9 Start knob..................................9 Indicator Lights................................9 DC Circuit Breaker...............................10 Engine ECO Control..............................10 Parallel Outlets................................10 Battery Switch................................11 Push Button Start/Stop..............................11 Ground Terminal.................................11 Assembly ....................................12 Connecting Generator to an Electrical System......................12 Adding Fuel.................................13 Adding / Checking Engine Oil ..........................13...
  • Page 3: Introduction

    . It is designed to supply electrical power to operate tools, appliances, camping equipment, lighting, or serve as a back up power source during power outages. Generator specification Model D8600i Voltage 120V/240V Frequency 60Hz Power(COP) 8.2kw...
  • Page 4: Safety Rules

    SAFETY RULES Safety Symbols Indicates a potentially hazardous situation which could result in serious injury or death of not avoided. Indicates a potentially hazardous situation which could result in damage to equipment or property. Read the operator’s Caution Wear noise protection instruction manual before use Carbon monoxide (CO) danger Fire hazard...
  • Page 5 SAFETY RULES Exhaust gas is poisonous; do not operate in an unventilated area CAN KILL YOU IN MINUTES! • Using a generator indoors • Carbon monoxide gas is a poisonous, odorless gas that can cause headache, confusion, fatigue, nausea, fainting, sickness, seizures, or death. If you start to experience any of these symptoms, IMMEDIATELY get fresh air and seek medical attention.
  • Page 6 SAFETY RULES This generator produces a very high voltage which could result in burns or electrocution causing serious injury or death. • Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or feet are wet. •...
  • Page 7 SAFETY RULES...
  • Page 8: Features

    FEATURES Oil maintenance Control Panel cover Fuel tank cap Recoil Handle Starter Muffler sheild Muffler Main Breaker Breaker Interrupteur principal Interrupteur ENGINE MOTEUR AC/CA 34A AC/CA 50A DC/CC 5V COMPTEUR MULTIPLE FUSIBLE Actif arrêt Battery Overload Low Oil EnMarche Surcharge Huile Bas AC/CA 120/240V Max.
  • Page 9: Control Panel Functions

    CONTROL PANEL FUNCTIONS Start knob Fuel off When the start knob is in the Fuel off position, the engine cannot start. Gasoline When the start knob is in the Gasoline position and the fuel switch is in the open position, the engine can start. Fuel off...
  • Page 10: Dc Circuit Breaker

    PARALLEL OPERATION CABLE KIT. WARNING! Never connect generators that are different models. • Only connect this generator to another D8600i Standard Generator or D8600i Companion Generator • Only use brands approved parallel operation cable kit to connect generators...
  • Page 11: Battery Switch

    CONTROL PANEL FUNCTIONS Battery Switch ENGINE MOTEUR When starting the generator, turn on the switch and turn off the switch when not in use. Push Button Start/Stop When the battery switch is on, long press to automatically start the generator, and press again to stop the generator.
  • Page 12: Assembly

    ASSEMBLY Connecting Generator to an Electrical System • If connecting generator to a building’s electrical system for standby power, The power from the generator must be isolated from the circuit breaker or alternative power source. The connection must comply with all electrical codes and applicable laws.
  • Page 13: Adding Fuel

    ASSEMBLY Adding Fuel • Set generator on a clean and level surface in an area that is well ventilated. • Remove fuel cap. • Insert a funnel into the fuel tank and carefully pour gasoline into the tank until fuel level reaches about 1 ½...
  • Page 14 ASSEMBLY NOTE: Check the engine oil level before each use or every 8 hours of operation. l Turn the generator off and allow the engine to cool for at least five minutes. l Place the generator on a level surface in a well-ventilated area. l Remove the bolt.
  • Page 15: Operation

    The load attached to the generator must therefore be reduced. How to Start Engine Generator start- Recoil status (D8600i) • Place generator on a level surface. All electrical loads MUST be disconnected from generator. Fuel off...
  • Page 16 OPERATION Fuel off Generator start-One push start & Remote start(D8600i) Gasoline • Place generator on a level surface. All electrical loads MUST be disconnected from generator. • Turn the knob switch to the Gasoline position. • Turn the battery switch to the ON position.
  • Page 17: How To Stop Engine

    OPERATION How to Stop Engine Generator stop - One push start & Remote start(D8600i) •Disconnect any electronic device. All loads MUST be disconnect from the generator. Never start or stop the engine with electrical devices plugged in to the receptacles.
  • Page 18: How To Attach Electronic Devices

    OPERATION How to Attach Electronic Devices 1. Before Starting generator • Make sure the generator is grounded (see page for instructions). • Make sure the attached load is within the generator rated output and the receptacle’s rated current. • Make sure all electrical cords and receptacles are in good condition. •...
  • Page 19: Ac Parallel Operation

    OPERATION AC Parallel Operation The D8600i generator has two models that are compatible with each other (Standard and Companion). It is possible to connect two D8600i generators to each other, using a parallel cable kit. • Connect PARALLEL OPERATION CABLES to two D8600i generators according to the instructions provided with the cable kit.
  • Page 20: Don't Overload Generator

    OPERATION Don’t Overload Generator Make sure you can supply enough rated watts for all electronic devices connected to the generator. Rated watts refer to the power a generator must supply to keep a device running. Surge watts refer to the power a generator must supply to start an electronic device.
  • Page 21: Maintenance

    MAINTENANCE Regular maintenance will extend the life of this generator and improve its performance. The warranty does not cover items that result from operator negligence, misuse, or abuse. To receive full value from the warranty, operator must maintain the generator as instructed in this manual, including proper storage. Before inspecting or servicing this machine, make sure the engine is off and no parts are moving.
  • Page 22: Checking Spark Plug

    MAINTENANCE Checking Spark Plug • Remove cap. Then remove spark plug cap. • Disconnect the spark plug wire from the spark plug. • Before removing the spark plug, clean the area around its base to prevent debris from entering the engine. •...
  • Page 23: Changing Oil

    MAINTENANCE Changing Oil • Place generator on a level surface. • Run the generator for several minutes until the engine is warm. Turn off generator. • Remove screws, then remove outer casing. • Remove the crankcase dipstick. • Place an oil pan underneath the engine. Tilt generator to collect used oil. Allow oil to drain completely. •...
  • Page 24: Air Filter

    MAINTENANCE Air Filter • To clean, remove the screws then remove outer casing. • • Remove the foam element. • Wash the foam element in solvent and let dry. • Pour a small amount of oil on the foam element then squeeze out, but do not wring out, excess oil.
  • Page 25: Fuel Filter

    MAINTENANCE Fuel Tank Filter • • • • • Install fuel cap. Fuel Filter • To clean, remove screws, remove outer casing, and drain fuel. • Lift and hold onto the clamp, then remove hose from tank. • • • •...
  • Page 26 MAINTENANCE How to drain fuel • Turn the switch to the “OFF” position. • • Use a siphon to transfer gasoline from generator into a gasoline approved container. • Wipe up any spilled fuel with a clean rag. • Start generator engine and let it run until it stops and all remaining fuel is consumed. Do not connect electronic devices to generator during this process.
  • Page 27: Troubleshooting

    TROUBLESHOOTING Problem Cause Solution Generator is running, but does not 1. DC Circuit Breaker is “OFF” 1. Turn DC Circuit Breaker “ON” supply power. 2. Green AC Pilot Light Indicator is off. 2. Stop engine and restart. 3. Poor connection 3.
  • Page 28: Diagrams

    DIAGRAM...

Table of Contents