Advertisement

Quick Links

Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Please read this manual BEFORE installing and
operating this fireplace.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Model: BH2818i
WARNING:
FIRE OR EXPLOSION HAZARD
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
carbone, lesquels sont reconnus dans l'État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
227 Industrial Park Rd. • South Pittsburg, TN 37380 •
Phone: 423-403-4031 • Web: www.breckwell.com
renseignements, veuillez consulter le site www.P65warnings.ca.gov
CALIFORNIA PROPOSITION 65 WARNING:
reproductive harm. For more information, go to www.P65warnings.ca.gov
Report # F18-426R1
853782C-1004N

Advertisement

Table of Contents
loading

Summary of Contents for Breckwell BH2818i

  • Page 1 State of California to cause cancer, birth defects and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov Report # F18-426R1 CONSUMER: Retain this manual for future reference. 227 Industrial Park Rd. • South Pittsburg, TN 37380 • Phone: 423-403-4031 • Web: www.breckwell.com 853782C-1004N...
  • Page 2 After-market: Completion of sale, not for purpose of resale, from the manufacturer. Note: Register your product by using your smart phone with the QR code. Save your receipts with your records for any warranty claims. You can also register your product online at www.breckwell.com/product-registration...
  • Page 3: Appliance Dimensions

    Appliance Dimensions Physical Dimensions Left Side View Right Side View inches Back Width 20 - 7/8 Depth (from back of surround) C Height (to top of exhaust tube) 24 - 5/8 Width 32 - 7/16 Back of Surround to Gas Line Access 7 - 5/8 Bottom to Gas Line Access 1 - 5/8...
  • Page 4: Safety Label

    Safety Label NOTE: This image is only an example. The label on the actual unit will vary slightly. FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    Requirements For The Commonwealth Of Massachusetts following requirements reference various size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL Massachusetts and national codes not contained in OBSTRUCTIONS”. this manual. For all sidewall horizontally vented gas INSPECTION fueled equipment installed in every dwelling, building The state or local gas inspector of the side wall or structure used in whole or in part for residential horizontally vented gas fueled equipment shall not...
  • Page 6: Before You Start

    Before You Start WARNING: Read this owner’s manual carefully and completely before trying to assemble, operate, or service. Any change to this appliance or its controls can be dangerous. Improper installation or use can cause serious injury or death from fire, burns, explosions, electrical shock and carbon monoxide poisoning. This is a vented product.
  • Page 7: Product Features

    17. This appliance, when installed, must be electrically to inspect and if needed replace any part of the grounded in accordance with local codes or in the control system and any gas control which as been absence of local codes, with the National Electrical under water.
  • Page 8: High Elevations

    Gas Pressures Gas Specifications & Orifice Size Natural Propane (LP) Max. Input Min. Input Orifice Fuel BTU/h BTU/h Size Inlet Minimum 5.0” w.c. 12.0” w.c. Nat. 26,000 14,000 Inlet Maximum 10.5” w.c. 14.0” w.c. Natural Gas LP Gas 24,000 12,000 Manifold Pressure 3.8”...
  • Page 9: Chimney Specifications

    EXISTING FIREPLACE OPENING MINIMUM REQUIREMENTS inches Height Front Width C Depth Back Width CHIMNEY SPECIFICATIONS WARNING: Any chimney clean-outs must fit properly. This fireplace insert is to be installed into a solid fuel masonry or factory built non- combustible fireplace that has been installed in accordance with the national, provincial, state, and local building codes.
  • Page 10: Minimum Termination Clearances

    MINIMUM TERMINATION CLEARANCES Inside corner detail Fixed closed Fixed Operable closed Operable Legend: = Vent terminal = Air supply inlet = Air where terminal is not permitted Canadian installation US installations Clearance above grade, veranda, porch, deck, or 12” (30 cm) 12”...
  • Page 11: Inspect And Clean Existing Chimney

    Installation Preparation NOTE: This gas fireplace insert is approved for installation in masonry and factory-built solid fuel burning fireplaces. CAUTION: Any removed parts must be capable of re-installation if this insert is ever removed. Removal of rivets or screws is acceptable. INSPECT AND CLEAN EXISTING CHIMNEY Verify existing chimney is constructed of non-combustible material.
  • Page 12: Installation

    Installation CO-LINEAR VENT SYSTEM CAUTION: Proper operation of this insert requires the exhaust and combustion air pipes to be connected to the correct collar, on both the termination kit and the gas fireplace insert air duct. The fireplace insert air duct exhaust is located on the right side. Install termination cap on the right side 1.
  • Page 13: Connect Vent Pipe To Air Duct

    CONNECT VENT PIPE TO AIR DUCT CAUTION: Proper operation of this appliance requires exhaust and combustion air pipes to be connected to the correct collar, on both the termination kit and the gas fireplace insert air duct. 1. Place previously removed air duct into existing fireplace opening.
  • Page 14: Gas Line Connection

    Gas Line Connection GAS CONVERSION (SOLD SEPARATELY) CAUTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code. This fireplace is manufactured for use with natural gas. Follow the instructions included with the conversion kit if converting to LP gas.
  • Page 15: Glass Frame Assembly

    Logs, Liner, Safety Barrier, & Surround Installation Do not place logs directly over burner port holes. Improper log placement may affect flame CAUTION: appearance and cause excessive soot to build upon the logs and glass. • If converting to LP (propane) gas, complete the conversion before installing the log set. Follow the conversion instructions included with the kit.
  • Page 16: Control Board

    3. Lift glass assembly up and off of the (2) tabs located at the top of the firebox. INSTALL GLASS ASSEMBLY 1. Align the slots on top of the glass assembly over the tabs at the top of the firebox while lowering the bottom of the glass assembly into position.
  • Page 17 Wiring Schematics -17-...
  • Page 18: Replacement Parts And Service

    It is important to clean the flame sensor rod using emery cloth if flame rectification problems are encountered after use for a few months. Environmental factors beyond the control of Breckwell can cause flame rectification concerns. HOW TO ACCESS COMPONENTS The descriptions below show where the main components are located and how to access them for service.
  • Page 19: Valve Assembly

    VALVE ASSEMBLY Pilot Top Shutter Cable Tube MTG Brkt Shutter Cable Bulk Head Shutter Gas Pilot Adjustment Sleeve Pilot MTG Box Burner Weldment Orifice Shutter Adj. Burner Bottom Assembly Mount Plate Shutter Adj. Top Assembly Valve Assembly Mount Burner Accent Light Control Module Blower -19-...
  • Page 20: Installation Checklist

    Installation Checklist All items on the checklist must be completed. The venting system is installed by an approved service person in accordance with instructions and local codes. Vertical vent cap is installed "right-side-up" and tightly sealed to the structure per instructions. Vent Caps are approved.
  • Page 21: Remote Control Functions

    REMOTE CONTROL FUNCTIONS NOTE: You will hear a beep once every time a remote-control button is LCD Display pressed, signaling that the command has been received. On/Off Button Locate the four function buttons on the remote control: Thermostat 1. On/Off Button: This button turns the fireplace on or off. When this Button button is depressed, and the system is off, the pilot will ignite.
  • Page 22 UNDERSTANDING YOUR REMOTE-CONTROL ICONS system will remember your selected fan speed until you manually change it. Your remote control displays and controls the following functions. See below for detailed control icon explanations. Child Lock Transmission Low Battery Room Thermostat Temperature Off/On/Smart Accent Light: This function controls the accent light CPI Mode...
  • Page 23: First-Time Lighting Instructions

    First-Time Lighting Instructions WARNING: WARNING: If you do not follow these instructions WHAT TO DO IF YOU SMELL GAS exactly, a fire or explosion may result causing • Do not light any fireplace. property damage, personal injury, and loss of life. •...
  • Page 24: Where Can I Find The Model And Serial Numbers

    Report # F18-427 227 Industrial Park Road, South Pi�sburg, TN 37380 • Phone: 423-403-4031 • Web: www.breckwell.com 853783B WHAT HAPPENS WHEN FIRST LIT? There is a curing period.
  • Page 25 Adhesives, glue, wall substrate, wall finish material, paints, and polishes are common materials that if used incorrectly will cause odor issues. Breckwell is not responsible for any odor issues caused by materials used. If you have any additional questions or concerns, contact your authorized dealer or email service www.breckwell.com.
  • Page 26: Burner Flame Appearance

    3. Before re-installing glass, have qualified service person check the operation of the pilot and cycle the burner per lighting instructions. Be sure all items in lighting and installation checklists are completed. 4. Periodic visual check of pilot flames is required. Pilot flame must overlap flame sensor and burner ignition ports always.
  • Page 27: Why Did My Thermostat Disappear From My Remote

    CHANGING THE BATTERIES IN MY REMOTE CONTROL? When the remote-control batteries are low, a battery icon will appear on the LCD display of the remote control before all battery power is lost. When the batteries are replaced, this icon will disappear. WHY DID MY THERMOSTAT DISAPPEAR FROM MY REMOTE? When reinstalling batteries, the thermostat may have been pressed while the batteries were changed.
  • Page 28: Burner Flame Adjustments

    INLET PRESSURE TEST NOTE: Make sure to apply these incoming pressure test with all other gas fireplaces on, or at full capacity in the house for proper pressure reading. CAUTION: If the inlet pressure reading is too high or too low, contact the gas company. Only a qualified gas service technician should adjust incoming gas pressure.
  • Page 29: Troubleshooting

    2. If flame is too “blue,” push the air shutter knob in (close) in small 1/8” increments until flame turns desired realistic “orange” color. 3. If flame is too “orange” or is causing sooting on viewing glass, pull air shutter knob out (open) in approx. 1/8” increments until sooting stops.
  • Page 30 ON/OFF rocker switch in OFF position Gas supply turned off Check Check for multiple shut-offs in the supply line. Gas supply turned off Verify gas supply is turned on. Consult with plumber or gas supplier. Low gas supply Check LP (propane) tank. Refill if necessary. Wiring disconnection or improper wiring Check for faulty or incorrect wiring.
  • Page 31: Burner And Pilot System

    • Inspect the glass for cracks, scratches, and nicks. • Verify the glass assembly is properly intact and not damaged. • Replace the glass and the assembly as necessary. • Only Breckwell Home Products will supply the replacement of glass assembly as a complete unit. -31-...
  • Page 32 NOTES -32-...
  • Page 33 NOTES -33-...

Table of Contents