Breckwell BH2818i Instructions Manual page 30

Table of Contents

Advertisement

Main burner flame will not light
Pilot and burner extinguish
while in operation
Soot appears on glass
Flame burns blue and lifts off
burner
No reaction to command
CAUTION: Installation and repair shall only be done by a qualified service person. The fireplace should be
inspected before use by a qualified service person. It is required to be inspected at least once a year by a
professional service person.
ON/OFF rocker switch in OFF position
Gas supply turned off
Low gas supply
Wiring disconnection or improper wiring
Plugged main burner orifice
Pilot flame
Remote control not working properly
No call for heat
No LP (propane) gas in tank
Incorrect glass assembly installation
Incorrect vent cap installation
Vent cap blockage
Improper pitch on horizontal venting
Exhaust vent pipe leaking exhaust gases
back into firebox
Excessive draft
Improper log placement
Improper venturi setting
Incorrect vent cap installation
Vent cap blockage
Improper venturi setting
Incorrect vent cap installation
Blockage or leakage of the vent system
Battery back batteries or remote control
batteries low
No communication between remote
control and ignition module
A maximum number of failed ignitions or
flame restorations has been reached
Gas supply turned off Check
Check for multiple shut-offs in the supply line.
Verify gas supply is turned on.
Consult with plumber or gas supplier.
Check LP (propane) tank. Refill if necessary.
Check for faulty or incorrect wiring.
Remove blockage.
Verify the pilot flame is properly directed to
ignite burner. See pilot flame troubleshooting
above.
Replace batteries.
Verify remote control is powered ON and
thermostat operation is turned OFF.
Check LP (propane) tank. Refill if necessary.
Refer to Glass Frame Assembly Section
Adjust if necessary.
Remove debris if necessary.
1/4 in. (6 mm) rise per foot (30 cm) is required
on horizontal venting
Check for leaks and repair if necessary.
A restrictor may need to be installed or
modified.
Refer to Log Set Installation section.
Venturi air shutter may need to be opened
slightly to allow more air into the gas mix.
Refer to Burner Venturi section.
Adjust if necessary.
Remove debris if necessary.
Venturi air shutter may need to be opened
slightly to allow more air into the gas mix.
Refer to Burner Venturi section.
Adjust if necessary.
Check the vent pipes for leaks, and the
vent cap for debris. Repair the vent pipes or
remove debris from vent cap, if necessary.
Replace batteries.
Reprogram remote control to the ignition
module.
Reset ignition module.
-30-