Breckwell BH2818i Instructions Manual page 22

Table of Contents

Advertisement

UNDERSTANDING YOUR REMOTE-CONTROL ICONS
Your remote control displays and controls the following
functions. See below for detailed control icon
explanations.
Transmission
Thermostat
Off/On/Smart
Thermostat
Temperature
Flame
Height
Fan Speed
ICON DETAILS
Mode Button: Pressing the mode button toggles
between the various available functions: flame height,
fan speed, accent light intensity and rear burner on/
off.
Flame Height: Six flame height levels are available.
While the flame height icon is displayed, pressing the
up or down button once will increase or decrease the
flame height by 1 of 6 levels.
If the flame height is at Level 1 and the down button is
pressed, all burners will turn off.
If in IPI mode, the pilot will also extinguish.
If in CPI mode, the pilot will remain on. NOTE: If in Smart
Thermostat, the flame height function is not available
for manual adjustment. In Smart Thermostat, the flame
height regulates automatically.
Fan Speed Control: The fan speed can be adjusted
through 6 speeds and off. To activate this function,
press the Mode button until it displays the fan icon. Use
the up/down arrow button to turn on, off, or adjust the
fan speed. Once you set the desired fan control, the
Child Lock
Low Battery
Room
Temperature
CPI Mode
Light Intensity
FLAME OFF
FLAME LEVEL 1
FLAME LEVEL 5
FLAME LEVEL MAXIMUM
system will remember your selected fan speed until you
manually change it.
Accent Light: This function controls the accent light
functions. Pressing the up button in this mode will turn
on the accent light and allow you to control the 6 levels
of intensity. Once you set the desired light level, the
system will remember your selection until you manually
change it.
IPI AND CPI MODES
Intermittent Pilot and Continuous (Standing) Pilot
Features - First lights a pilot then uses the pilot to ignite
the main burners. The pilot can be set in the CPI
(Continuous Pilot Ignition) mode to allow the pilot to
remain on indefinitely by setting the remote control
to CPI mode. If the remote control is set to the IPI
(Intermittent Pilot Ignition) mode, the pilot will only light
and remain ON while the main burners are operating.
IPI Mode: This mode turns the pilot off when not in use
and only lights the pilot automatically when a call for
heat is made by the remote control.
CPI Mode: If set to CPI mode, the pilot will ignite and
remain on at all times.
SETTING TO IPI OR CPI MODE
With the remote control off, press the MODE button. You
will see either "CPI" or "IPI" displayed on the screen.
Press the UP arrow button to set "CPI" mode and press
the down arrow button to set "IPI" mode. Once set to
the desired setting, press On/Off button to activate.
Recommended: Keep in CPI mode. While not
mandatory, this will keep the chimney heated for
proper updraft during burner ignition, and it will also
eliminate excessive condensation of exhaust vapors on
the door glass. NOTE: The snowflake icon will be visible
on the display always when in CPI mode.
Leaving it in CPI mode will keep the body warm and
eliminate cold drafts and heat loss to the cold air that is
trapped inside the firebox.