C Checking the brake pedal stroke
Pedal stroke
Less than 100 mm at each pedal
1. Disengage the brake pedal lock.
2. Depress the brake pedal several times.
3. Step on the right-hand pedal and measure the level
difference (pedal stroke) between this pedal and the
left-hand pedal.
4. Do the same for the left-hand pedal.
(1) Brake pedal (LH)
(2) Brake pedal (RH)
(3) Brake pedal lock
C Checking the equalizer working level
(anti-imbalance device)
1. Gently step on both brake pedals at once.
2. Further step on the right-hand pedal (the left-hand
pedal slightly raises itself) and measure the level
difference between the pedals.
3. Do the same for the left-hand pedal.
Equalizer working
Level difference of over 10 mm
level
between both pedals
BAdjusting Parking Brake Lever
To avoid personal injury or death:
A Stop the engine and chock the wheels before
checking parking brake.
Proper parking brake
lever free travel
1. Raise the parking brake lever to the parking position
while counting the ratchet sound made by the parking
brake lever.
2. If adjustment is needed, loosen the lock nut and adjust
the parking brake cable length with in acceptable limit.
(A) "PEDAL STROKE"
2 notches (Ratchet sound 2)
3. Retighten the lock nut.
(1) Parking brake cable
(2) Lock nut
BChecking Battery Condition
To avoid the possibility of battery explosion:
For
the
refillable
instructions below.
A Do not use or charge the refillable type battery
if the fluid level is below the LOWER (lower limit
level) mark. Otherwise, the battery component
parts may prematurely deteriorate, which may
shorten the battery's service life or cause an
explosion. Check the fluid level regularly and
add distilled water as required so that the fluid
level is between the UPPER and LOWER levels.
To avoid personal injury or death:
A Never remove the battery cap while the engine
is running.
A Keep electrolyte away from eyes, hands and
clothes. If you are spattered with it, wash it
away completely with water immediately and
get medical attention.
A Keep open sparks and flames away from the
battery at all times. Hydrogen gas mixed with
oxygen becomes very explosive.
A Wear eye protection and rubber gloves when
working around battery.
The factory-installed battery is of non-refillable
type. If the indicator turns white, do not charge the
battery but replace it with new one.
PERIODIC SERVICE
type
battery,
follow
133