Kubota M100GX-II Operator's Manual page 173

Table of Contents

Advertisement

BChecking CAB Isolation Cushion
Check the cushion for any breakage or fatigue. Replace
them if they are deteriorated.
BChecking Exhaust Manifold
Consult your local KUBOTA Dealer for this service.
BChecking DPF Differential Pressure
Sensor Pipe
Consult your local KUBOTA Dealer for this service.
BChecking EGR Pipe
Consult your local KUBOTA Dealer for this service.
EVERY 2 YEARS
BFlushing Cooling System and Changing
Coolant
To avoid personal injury or death:
A Do not remove radiator cap while coolant is
hot. When cool, slowly rotate cap to the first
stop and allow sufficient time for excess
pressure to escape before removing the cap
completely.
1. Stop the engine and let it cool down.
2. To drain the coolant, loosen the clamp band and
remove the drain plug and remove the radiator cap.
The radiator cap must be removed to completely drain
the coolant.
3. After all coolant is drained, install the drain plug
securely.
4. Fill with clean soft water and cooling system cleaner.
5. Follow directions of the cleaner instruction.
6. After flushing, fill with clean soft water and anti-freeze
until the coolant level is just below the port.
7. Fill with clean water and anti-freeze up to the upper
line of recovery tank.
8. Install the radiator cap securely.
9. Start and operate the engine for a few minutes.
10. Stop the engine. Check coolant level and add coolant
if necessary.
11. Properly dispose of used coolant.
Tractor model
M100GX-II, M110GX-II
M128GX-II, M135GX-II
Coolant capacity
10.1 L
14.6 L
PERIODIC SERVICE
(1) Drain plug
(1) Radiator cap
(2) Recovery tank
(1) Drain plug
149

Advertisement

Table of Contents
loading

This manual is also suitable for:

M110gx-iiM m128gx-iiM135gx-ii

Table of Contents