- The power cable must only be replaced (for Symbol meaning example if damaged) by a qualified contrac- Material losses (appliance damage, consequential losses and environmen- tor authorised by the manufacturer, using an tal pollution) Appliance disposal original spare part. www.stiebel-eltron.com VCR 180 ECN |...
The outdoor air absorbs heat taken from the extract air. This enables a large proportion of thermal energy to Note be recovered. All measurements are given in mm unless stated oth- erwise. | VCR 180 ECN www.stiebel-eltron.com...
Frost prot.: The preheating coil for frost protection is switched on. on the display. Fan disable: The symbol is displayed in the event of the "Enable fan" is set to "Off". Settings Switching the appliance on f Plug the appliance into a standard socket. www.stiebel-eltron.com VCR 180 ECN |...
4.3.2 Selecting the fan setting f Using the Touch-Wheel, select the fan setting "Stage 1" or "Stage 2". Press "OK". | VCR 180 ECN www.stiebel-eltron.com...
The fan program is now set. f In standard view, select "Time program mode". Press "OK" to activate the fan program. Filter reset f After changing the filters, set the "Filter reset" to "On". www.stiebel-eltron.com VCR 180 ECN |...
Page 8
Prog. unit software Touch boost Air flow rate Only for qualified contractors The "Touch boost" lets you adjust the reaction speed of the Touch- Wheel and the sensor keys. | VCR 180 ECN www.stiebel-eltron.com...
Description Classification in ac- Quan- cordance with ISO 16890 tity f Ensure that the direction of air flow through the filter is FMS G4 VCR 180 ECN Coarse particle ISO Coarse > 60 % (G4) correct. filter product name Description Classification in ac- Quan- cordance with EN 1822-...
Alternate operation means that, when the combustion equipment is commissioned, the mechanical ventilation system is switched off and/or cannot be started. Alternate operation must be ensured by appropriate measures, e.g. automatically enforced shutdown of the ventilation unit. | VCR 180 ECN www.stiebel-eltron.com...
- The installation room must be free from the risk of frost. Acceptance must be carried out by a specialist. In case of doubt, - The appliance must be installed horizontally. you must involve an independent expert in the acceptance pro- cedure. www.stiebel-eltron.com VCR 180 ECN |...
(see chapter "Preparations / Installation site / Minimum clearances"). f Drill holes in the ceiling for mounting the appliance with threaded pins or double ended screws. f Fit the following parts onto each threaded pin in the se- quence described. | VCR 180 ECN www.stiebel-eltron.com...
Carried voices should be avoided by designing the duct with separate branches to the vents. If necessary, insulate the supply air ducts, e.g. if they are mounted outside the insulated wall panel. www.stiebel-eltron.com VCR 180 ECN |...
Secure the wall mounted enclosure to the flush box or to the wall using the screws provided. 10.4 Electrical connection WARNING Electrocution Carry out all electrical connection and installation work in accordance with national and regional regulations. | VCR 180 ECN www.stiebel-eltron.com...
X11-2 +5 V DC unit, there is a risk of injury. X11-3 Do not commission the unit until the air ducts are firmly X11-4 connected to it. www.stiebel-eltron.com VCR 180 ECN |...
The fans are deactivated in the delivered condition. Exhaust air fan control f Set the "Enable fan" parameter to "On". Exhaust air fan speed Exhaust air flow rate m³/h | VCR 180 ECN www.stiebel-eltron.com...
Page 18
"Humidity threshold". Frost protection Temp. to enable frost protection The unit only activates frost protection if the outdoor air temper- ature drops to the value that can be set in this parameter. | VCR 180 ECN www.stiebel-eltron.com...
You can remove the cover of the float module. During assembly, ensure that the bevelled side of the float magnet faces upwards. f Push the cover back onto the float module. www.stiebel-eltron.com VCR 180 ECN |...
Page 20
Push the fan units back into the appliance. f Reconnect the fan cables. f Fit the control panel cover. f Slide the cross-countercurrent heat exchanger back into the appliance. f Push the wedge back in again. | VCR 180 ECN www.stiebel-eltron.com...
Check the sensor of the currently selected voltage after disconnecting one fan stage. The appliance of the following sensor plugs: cannot provide humidity X15, X16, X23, X24. Replace the protection. sensor. Replace the electronic assembly. www.stiebel-eltron.com VCR 180 ECN |...
Specification 17. Specification 17.1 Dimensions and connections 1036 1113 VCR 180 ECN b07 Electrical connection Outdoor air Diameter g04 Exhaust air Diameter Extract air Diameter g06 Supply air Diameter Remote control | VCR 180 ECN www.stiebel-eltron.com...
Page 23
Specification 17.2 Fan diagram The graph shows the pressure drop for examples of air distribution systems. Application range Maximum fan curve Air flow rate [ m³/h ] System curves Average value, static pressure [Pa] www.stiebel-eltron.com VCR 180 ECN |...
Page 24
Anschluss Netz Nicht belegt Frostschutzheizung Nicht belegt Netzleitung Zuluftluefter Sensor Temp. & Luftf. ABL Netzleitung Fortluftluefter Nicht belegt Nicht belegt Ohne Funktion Interner Schwimmerschalter Ohne Funktion | VCR 180 ECN www.stiebel-eltron.com Sensor Temperatur AUL Ohne Funktion Nicht belegt Steuerleitung Fortluftluefter...
Min. ambient conditions, installation room (temperature) °C Max. ambient conditions, installation room (temperature) °C Available external pressure at max. air flow rate Heat recovery level Further details VCR 180 ECN 239546 Maximum height for installation 2000 www.stiebel-eltron.com VCR 180 ECN |...
Page 26
This will not affect warranties issued by any importers. Environment and recycling We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations. | VCR 180 ECN www.stiebel-eltron.com...
Page 27
FILTER INSPECTION LOG Filters in appliance Date Filter dirty Filter cleaned Filter changed Filters in extract air/supply air apertures (if present) Date Filter dirty Filter cleaned Filter changed www.stiebel-eltron.com VCR 180 ECN |...