Cleaning And Replacing The Seat And Plug - Samson 44-2 Mounting And Operating Instructions

Table of Contents

Advertisement

NOTICE
!
Risk of regulator damage due to the use of
unsuitable lubricants.
Only use lubricants approved by SAMSON.
Note
SAMSON's After-sales Service can support
you concerning lubricant, tightening torques
and tools approved by SAMSON.
Note
The regulator was checked by SAMSON
before delivery.
− Certain test results certified by SAMSON
lose their validity when the regulator is
opened. Such testing includes seat leakage
and leak tests.
− The product warranty becomes void if
service or repair work not described in
these instructions is performed without
prior agreement by SAMSON's After-sales
Service.
− Only use original spare parts by
SAMSON, which comply with the original
specifications.
Tip
SAMSON's After-sales Service can support
you in drawing up an inspection and test
plan for your plant.
EB 2623-1 EN
8.1 Cleaning and replacing the
seat and plug
DANGER
!
Risk of personal injury due to preloaded
springs.
Regulators in combination with preloaded
set point springs are under tension. These
regulators can be identified by the red
warning label on the actuator's set point
springs.
− Before starting any work on the springs,
relieve the compression from the preloaded
springs.
− Only use the SAMSON disassembly tool
(1280-4052).
NOTICE
!
Risk of regulator damage due to over- or
under-torquing.
Observe the specified torques when tighten-
ing regulator components. Excessive tighten-
ing torques lead to parts wearing out more
quickly. Parts that are too loose may cause
leakage.
Observe the specified tightening torques.
NOTICE
!
Risk of damage to the facing of the seat
and plug due to incorrect service or repair.
Always replace both the seat and plug.