Troubleshooting the Single Slot USB/Serial Cradle (Continued)
Table 7-3
Symptom
FR6076 battery is
not charging.
Spare battery is not
charging.
During data
communication, no
data transmits, or
transmitted data was
incomplete.
 
Possible Cause
FR6076 was
Ensure cradle is receiving power. Ensure FR6076 is seated
removed from
correctly. Confirm main battery is charging under
cradle or
System
cradle was
six hours.
unplugged from AC
power too soon.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty
battery.
The FR6076 is
Remove and re-insert the FR6076 into the cradle, ensuring it is
not fully seated in
firmly seated.
the cradle.
Ambient
Move the cradle to an area where the ambient temperature is
temperature of the
between 0°C (32°F) and 35°C (95°F).
cradle is too warm.
Extreme battery
Battery does not charge if ambient temperature is below 0°C (32°F)
temperature.
or above 45°C (113°F).
Battery not fully
Remove and re-insert the spare battery in the cradle, ensuring it is
seated in charging
firmly seated.
slot.
Battery inserted
Re-insert the battery so the charging contacts on the battery align
incorrectly.
with the contacts on the cradle.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty
battery.
Ambient
Move the cradle to an area where the ambient temperature is
temperature of the
between 0°C (32°F) and 35°C (95°F).
cradle is too warm.
FR6076 removed
Replace FR6076 in cradle and retransmit.
from cradle during
communications.
Incorrect cable
See the system administrator.
configuration.
Communication
Perform setup as described in the FR6076 Integrator Guide.
software is not
installed or
configured properly.
Maintenance & Troubleshooting