Contents Introduction to the SAN-10 ........................... 3 Features ..................................3 Monitor ..................................4 LCD Display ................................4 Operation ................................. 5 Power Button................................... 5 Menu Status ..................................... 6 Alarm Threshold ..................................7 Man Down Alarm ................................... 8 Access Data Log ..................................8 Calibration ................................
If CO2 buildup occurs, it will show the level on screen, flash, alarm and vibrate. In addition, the SAN-10 includes built-in data logging and a man-down alarm that uses an accelerometer to set off the alarm if a sudden shock to the unit (like the wearer falling down) occurs.
Operation Power Button 1. When the Monitor is turned off, press the power button to turn on the unit. 2. When the Monitor is turned on, press the power button for 3 seconds to turn off the unit. When the unit is first turned on, it performs a 5 second countdown, then enters normal display with current CO2 readings displayed.
Menu Status By pressing the menu button for 5 seconds, the unit enters into "Menu status". There are six menu items by pressing the menu button shortly to loop switching between AIR, N2, Hx.x, Lx.x, A ON/OFF, SC, Px, Log and E (exit). The menu times are further described in the table below: Menu Items Functional Description...
Warning Low Alarm: LED will flash and audible alarm will sound 2x / sec. There are high and low alarm thresholds in the SAN-10. Both high and low alarms have five thresholds: 5000ppm, 5000ppm TWA, 1.0%, 1.5%, 2.0%, 2.5%, 3.0%, 3.5% and 4.0%.
Access Data Log The SAN-10 has an internal storage system that acts like an SD card. Simply connect the SAN-10 to a PC using the included USB-C charging cable. The device will connect to a COM port of the PC. You will be able to access all saved data this way.
Calibration Step 1. Power the unit on by pressing and holding the power button for 3 seconds Step 2. Press and hold the ºF/ºC button for 5-10 seconds to open the first menu Step 3. Use the ºF/ºC button to scroll through the first menu which will read: (Ambient Air Calibration Option) (Zero Nitrogen Calibration Option) L 0.5...
Maintenance The SAN-10 is a low maintenance safety monitor that requires little maintenance. It is recommended to calibrate the internal NDIR CO2 Sensor annually. This calibration can be completed in the field, or the monitor can be returned to CO2Meter to perform the calibration.
Product Returns If any Product fails under normal use, you may return it to us, by first submitting a customer case support ticket (submission here). Policies and procedures for returns and refunds related to the same are located at www.co2meter.com/pages/faq. All returns for refund after thirty (30) days from shipment of the applicable product will incur a 25% re-stocking fee.