Contents INTRODUCTION ........................... 3 FEATURES ............................ 3 DESCRIPTION ..........................4 LCD DISPLAY ..........................4 OPERATION ..........................5 Power Button .......................... 5 Daily Bump Test ........................5 MENU OPTIONS .......................... 6 1. Set Alarm Threshold ......................6 2. Set Temperature Units ......................7 3.
In addition to measuring the CO2 concentration, the monitor displays temperature and relative humidity. The SAN-0001 Pocket CO2 Monitor and Data Logger is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
DESCRIPTION 1. Green LED - good 2. Yellow LED - normal 3. Red LED - warning 4. LCD display 5. Power button 6. Menu button 7. Set & Home button 8. Next button 9. High CO2 alarm LED 10. USB charging port 10, 11.
OPERATION For daily operation, you should only need to perform 3 steps: power the monitor on, verify that the battery is charged, and perform a bump test. Power Button 1. Press the power button to turn the monitor on. 2. When the monitor is on, press the power button for 3 seconds to turn it off.
Quick Bump Test The quick bump test will only work if the alarm is set to the factory default of 5,000ppm. 1. Turn the device on and wait for it to complete the 5 second warm up cycle. 2. Place the top end of the monitor close to your mouth and breathe into the holes repeatedly.
2. Set Temperature Units Select temperature scale °Centigrade or °Fahrenheit. 1. Press Menu 2 times to select temperature units. 2. Press Next to switch between °C or °F. 3. Press Set to save and return to normal display. 3. Calibration The monitor should be calibrated at least annually and can be calibrated either atmospheric (outdoor 400 PPM CO2) or Zero with 100% Nitrogen (...
Turn off the gas and let the monitor stabilize. It will return to the normal indoor CO2 level. Two different SAN-0001 monitors may show different CO2 levels after calibration. If they are within 40ppm ±3% of the actual CO2 level, they are within the sensor’s specifications.
Note: before exporting data to a PC, you must install the software and drivers first, then connect the monitor to your PC using a Micro USB to Standard USB cable (included). DATA LOGGING SOFTWARE Included with your monitor is our GasDataLogging Software.
Quick Start Guide 1) Install GasDataLogging from thumb drive or from the website at: http://www.co2meter.com/pages/downloads 2) You must install the software before connecting the monitor. After you have launched the GasDataLogging software, connect the monitor to the computer with the included USB cable.
Installing the Software Double click or select Run from the popup menu to launch the GasDataLogging executable program as shown in Figure 1. Figure 1:GasDataLogging Software IMPORTANT: THE FTD2XX.DLL FILE IS REQUIRED TO CONNECT THE MONITOR VIA USB. IT MUST BE IN THE SAME FOLDER AS THE GASDATALOGGING EXECUTABLE PROGRAM.
Downloading Data Once your monitor is connected to your computer, the Data Section allows you to download all the current logs stored in the monitor’s internal memory. When you click the Download Data button, a progress bar indicates the download process (See figure 3). Once download is complete, you will see all data including CO2 level, temperature and relative humidity in the Raw Data Window and the Graph Sections.
MAINTENANCE Calibration The SAN-0001 comes pre-calibrated from the factory. However, the CO2 sensor should be calibrated at least once a year, or as described in your company’s safety procedures. You can perform the calibration yourself, or you can return it to CO2Meter for factory calibration at a nominal fee.
Troubleshooting Cannot power on Press the Power Button for more than 0.5 seconds. Check that the Li-ion battery is charged. If monitor is charged but will not turn on, contact support. Monitor is not Verify that software and drivers are installed correctly before attaching recognized by monitor to PC.
WARRANTY The monitor comes with a one (1) year warranty starting from the date the monitor was shipped to the buyer. For more information visit our website: www.CO2Meter.com/pages/faq CONTACT US Support@CO2Meter.com CO2Meter, Inc. (386) 256-4910 Technical Support 131 Business Center Drive Ormond Beach, FL 32174 USA...
APPENDIX A: CO2 LEVELS AND GUIDELINES 1. CO2 Alarm Guidelines The Occupational Safety & Health Administration (OSHA) requires by law that workers must be protected from potentially dangerous high levels of CO2. There are 3 CO2 safety limits that must all be followed: •...
APPENDIX B: ALTITUDE CORRECTION CO2 sensor modules are calibrated at sea level designed automatically compensate for changes to CO2 at higher altitudes. The CO2 level will be approximately 3% lower for every increase of 1,000 feet (300m) in altitude. For example, at 5,000 feet a meter reading 400 ppm calibrated at sea level would read approximately 340 ppm.
SetBaudRate(FT_BAUD_57600); // Set baud rate to 57600 SetDataCharacteristics(FT_BITS_8, FT_STOP_BITS_1, FT_PARITY_NONE); Commands to download log from monitor: The server must send “SAN-0001” or “san-0001” ASCII code through the USB port to start the download. For example: 0X53 0X41 0X4E 0X2D 0X30 0X30 0X30...
Need help?
Do you have a question about the SAN-0001 and is the answer not in the manual?
Questions and answers