Information - Honeywell Sensepoint XCD Technical Manual

Hide thumbs Also See for Sensepoint XCD:
Table of Contents

Advertisement

Sensepoint XCD Technical Manual

2. Information

This Technical Manual is for use with the Sensepoint XCD range transmitters only.
The Start-up/Surge/In rush current is dependent on the type of power supply used. The typical start-up
current for Sensepoint XCD is less than 800 mA. Measure the start-up current using the specific power
supply before installation to ensure suitability for your application.
Honeywell Analytics can take no responsibility for installation and/or use of its equipment if not done so
in accordance with the appropriate issue and/or amendment of the Technical Manual.
The reader of this Technical Manual should ensure that it is appropriate in all details for the exact
equipment to be installed and/or operated. If in doubt, contact Honeywell Analytics for advice.
The following types of notices are used throughout this Technical Manual:
Identifies a hazardous or unsafe practice which could result in severe injury or death to
Identifies a hazardous or unsafe practice which could result in minor injury to
NOTE: Identifies useful/additional information.
Every effort has been made to ensure the accuracy of this document, however, Honeywell Analytics can
assume no responsibility for any errors or omissions in this document or their consequences.
Honeywell Analytics would greatly appreciate being informed of any errors or omissions that may be
found in the content of this document.
For information not covered in this document, or if there is a requirement to send comments/corrections
about this document, contact Honeywell Analytics using the contact details given on the back page.
Honeywell Analytics reserve the right to change or revise the information supplied in this
document without notice and without obligation to notify any person or organization of such
revision or change. If information is required that does not appear in this document, contact the
local distributor/agent or Honeywell Analytics.
WARNING
personnel.
CAUTION
personnel, or product or property damage.
EU Directive 2012/19/EU: Waste Electrical and Electronic Equipment
(WEEE)
This symbol indicates that the product must not be disposed of as general
industrial or domestic waste. This product should be disposed of through
suitable WEEE disposal facilities. For more information about disposal of this
product, contact your local authority, distributor or the manufacturer.
8
SPXCDHMANEN Issue 15

Advertisement

Table of Contents
loading

Table of Contents