This equipment is designed and constructed as to prevent ignition sources arising, even in the
event of frequent disturbances or equipment operating faults.
The sensor head must be fitted with the supplied weather protection and mounted so that the
sinter is pointing downward to provide ingress protection IPX6.
The weather protection is a potential electrostatic charging hazard. The manufacturer's
instructions should be observed.
The transmitter has a potential electrostatic charging hazard. To minimize the risk of
electrostatic discharge:
• Ground the transmitter adequately
• Install the transmitter in a manner that will prevent accidental electrostatic discharges,
e.g. ensure that objects do not rub against the housing etc.
• Clean the enclosure with a damp cloth when necessary
The purchaser should make the manufacturer aware of any External effects or Aggressive substances
that the equipment may be exposed to.
Note: The control card must have a suitably rated fuse.