Interface enablement
Print language selection
XEROX 4219/MRP AND 4215/MRP INSTALLATION PLANNING GUIDE
Flow control
Allows you to set the communication protocol to one of the
following:
XON/XOFF (default communication protocol)
Robust XON/XOFF
DTR
For Robust XON/XOFF the printer will send an XON every second
while waiting for data. Robust XON/XOFF is available only when
the printer interface is set for PostScript mode.
Baud rate
Allows you to select the baud rate for the serial interface.
Data width
Allows you to set the word length to one of the following:
7-bit
8-bit (default).
Parity
Allows you to set the parity at to one of the following:
None (default)
Odd
Even.
DTR Polarity
If DTR is selected for flow control the DTR polarity can be set
either high or low.
Other I/O (Twinax or Coax) interface
Allows you to enable or disable the Twinax or Coax interface.
When it is disabled no jobs will be processed from the Twinax or
Coax interface.
Allows you to select the following settings:
PS/PCL Sensing (default)
PostScript mode (Standard)
HP LaserJet emulation mode
PostScript mode (Binary)
Hexadecimal dump mode
PostScript mode (Tagged binary).
Note:
N
must be enabled and set for PS/PCL sensing.
PREPARING THE INSTALLATION CHECKLISTS
For 4215/MRP and 4219/MRP the Other I/O interface