SUPERIOR

WIRING DIAGRAMS

Wiring diagrams are provided here for reference purposes only. This information is also
provided on schematics attached directly to the appliance on a pullout panel located within the
control compartment.
WIRING DIAGRAM MILLIVOLT GAS VALVES
THERMOPILE
APPLIANCE- MOUNTED
ON/OFF SWITCH
TP-TH
TP
TH
GAS VALVE
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
WALL RECEIVER (OPTIONAL)
THERMOSTAT (OPTIONAL)
Figure 10: Wiring Diagram—
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
Millivolt Gas Valves
f i r e - p a r t s . c o m
FAN
(OPTIONAL)
JUNCTION BOX
Fireplace Model Number ________________________________________________
Fireplace Serial Number _________________________________________________
Date Installed _________________________________________________________
Type of Gas Used in Fireplace ____________________________________________
Dealer Name _________________________________________________________
• DIRECT-VENT GAS FIREPLACES (SDV35-N-2) • CARE AND OPERATION INSTRUCTIONS
®
BLOWER CONTROL CIRCUIT WIRING
Black
BK
Plug blower
R
W
into this
receptacle
GR
Blower
Ground
Figure 11: Junction Box Wiring
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
120V, 60HZ, 1PH
* Wall-mounted
ON/ OFF Blower
Switch or Variable
Speed Control Switch.
Junction Box
Tab
Broken
Hot
Side of
Red
Receptacle
Neutral
Side of
Receptacle
Tab Intact
Green
Ground
Screw
Field Wired
Factory Wired
CAUTION: LABEL ALL WIRES
PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER
AND DANGEROUS APPLIANCE
OPERATION.
ATTENTION : AU MOMENT DE
L'ENTRETIEN DES COMMANDES,
ÉTIQUETEZ TOUS LES FILS
AVANT DE LES DÉBRANCHER.
DES ERREURS DE CÁBLAGE
PEU-VENT ENTRAÎNER UN
FONCTIONNEMENT INADÉQUAT
ET DANGEREUX.

ORDERING REPLACEMENT PARTS

A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
With proper care and maintenance, your
appliance will provide many years of
enjoyment. If you should experience any
problem, first refer to the troubleshooting
guide in this manual. If problem persists,
contact your LHP dealer or distributor.
Normally, all parts should be ordered through
your LHP distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or
application of this system, please contact
your dealer or distributor.
LENNOX HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
visit us at www.LennoxHearthProducts.com
1-800-
655-2008

PRODUCT REFERENCE INFORMATION

We recommend that you record the important
reference information about your fireplace in
the space provided.
Please call Lennox Hearth Products for
the phone number of your nearest Lennox
Hearth Products dealer who will answer your
questions or address your concerns.