DSA E-Series (E2700)
Notice!
Some SAS ports might have a black plastic plug installed. Remove the plug before you attach
a cable to the port.
Notice!
On all E2700 controller-drive tray models, the expansion connectors to the drive trays are
always on the right side of the controllers from the rear view.
Notice!
If the storage array includes DE6600 drive trays, install those drive trays beginning from the
bottom of the rack so that the rack does not become top-heavy. A top-heavy rack has a
greater risk of falling over.
SAS ports on a DE6600 drive tray
As you install each cable, attach labels to the cable with the following information:
For example, if you are connecting controller A to the SAS IN port on ESM A in drive tray 1, the
label on the controller end of the cable will have this information:
CtA-Dch1, Dm1-ESM_A (left), In – Controller End
The label on the drive tray end of the cable will have this information:
Dm1-ESM_A (left), In, CtrlA
If you are connecting an ESM (Out) port to an ESM (IN) port, the label on the first drive tray
will have this information:
Dm1-ESM_A (left), OUT, DM1 ESM_B (left)
Bosch Sicherheitssysteme GmbH
1
2
1
ESM A
2
ESM B
3
SAS IN port
The controller ID (for example, controller A)
The ESM ID (for example, ESM A)
The ESM connector (In or Out)
The drive tray ID
Connecting the E2700 controller-drive tray to the drive trays | en
3
5
!
4
5
4
5
Installation manual
92040-14
SAS IN port
SAS Out ports
51
2016.12 | V2.1 | DOC