Troubleshooting - FRIGOGLASS Flex 35 Tall HC User Manual

Table of Contents

Advertisement

ENG

5. Troubleshooting

ALL ACCESS TO THE COOLING SYSTEM AND ELECTRICAL PARTS
(CHANGING LIGHTING OR REFRIGERATION DECK) MUST BE
PERFORMED BY AUTHORIZED SERVICE PERSONNEL ONLY.
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
5
In case the merchandiser is placed in very dusty and/or greasy
environment, the regular cleaning of the condenser by an authorized
technician is mandatory.
Keep the cooler in a stable position during cleaning, do not step on or
lean over the cooler.
Do not clean with sharp objects, flammable or corrosive liquids or
sprays.
Models Flex 35 Tall HC, Flex 45 HC, Flex 45 SZ [R600a], Flex 60
HC, Flex 60 SZ [R600a], Bar 150 [R600a], Bar 250 HD [R600a] and
Bar 250 SD [R600a] are equipped with HC refrigerant. All service
operations on cooling mechanism & gas charging should be
performed in a well ventilated environment or in open air. Do not
smoke during maintenance.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE
HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
Keep the glass door of the cooler closed during cooling mechanism
maintenance. The appliance will not stand stable when the
compressor is disassembled. If the compressor needs to be
replaced, use adequate support to stabilize the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.