Goodwe SEC1000 User Manual

Goodwe SEC1000 User Manual

Smart energy controller
Hide thumbs Also See for SEC1000:

Advertisement

Quick Links

User Manual
Smart Energy Controller
SEC1000
V1.1-2023-05-30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SEC1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Goodwe SEC1000

  • Page 1 User Manual Smart Energy Controller SEC1000 V1.1-2023-05-30...
  • Page 2: Table Of Contents

    2 Safety and Warning 3 Mounting 3.1 Mounting Instruction 3.2 Overview and Packaging 3.3 SEC1000 Installation 3.4 SEC1000 Grid Connection Diagram 4 Equipment Commissioning 4.1 Indicators and Button 4.2 Main functions of SEC1000 4.3 SEC1000 Backflow Prevention Function 5 Technology parameter...
  • Page 3: Symbols

    SEC1000. Otherwise, GoodWe will not assume the responsibility and quality assurance for the personal harm. • Make sure that the AC input voltage and input current match the rated voltage and current of SEC1000, otherwise the components will be damaged or cannot work properly,and GoodWe will not assume the responsibility and quality assurance for this case.
  • Page 4: Mounting

    3 Mounting 3.1 Mounting Instruction • SEC1000 must be installed where there is no significant shaking, shock vibration and no direct rain or snow. • SEC1000 shall be installed at eye level for easy operation and maintenance. • SEC1000 shoud not be installed near inflammable and explosive items.Any strong electro-magnetic equipment should be kept away from installation site.
  • Page 5: Sec1000 Installation

    • The installation location must be well ventilated • SEC1000 can be placed horizontally or installed vertically • The SEC1000 must be installed vertical or with a backward tilt less 15°.No sidwways tilt is allowed.The connection area must point downwards.Refer to Figure 3.3.1-1.
  • Page 6 (3)Place SEC1000 on the wall-mounted bracket as illustrated in figure 3.3.2-3 Figure3.3.2-3 1. SEC1000 can be placed horizontally to work, as shown in the figure 3.3.2-4. 2. SEC1000 should be placed in a fixed place indoors as shown in the figure3.3.2-5. Figure 3.3.2-4 Figure 3.3.2-5...
  • Page 7 Open the door of SEC1000 as shown in Figure 3.3.2-6. Figure 3.3.2-6 3.3.3 Port and wiring instructions The PE cable shall be connected first when install the equipment and be disconnected last when remove the equipment. Grounding Diagram ① Voltage Input Port(L1\L2\L3\N\PE) Input phase voltage range: AC60V-AC280V.
  • Page 8 ④ LAN Network port LAN SEC1000 uses this port when accessing a network cable;The access point is as shown in the "NET" position in the figure above. It is recommended to use network cables better than Super Five Type. After wiring, use the fire-proof mud to seal the port, to ensure its protective performance.
  • Page 9: Sec1000 Grid Connection Diagram

    Descriptions of internal communication ports of SEC1000 are as following. Port Description POWER DC Power Input (Occupied) Ethernet Interface DRED or RCR functional interface reserve COM1 485 interface1 with Inverter COM2 485 interface2 with Inverter COM3 485 interface3 with Inverter...
  • Page 10: Equipment Commissioning

    SEC1000 is connected to the computer software ProMate Blue light Off SEC1000 is not connected to the computer software ProMate Number of inverters actually acquired by SEC1000 is equal to the Blue light On parameter setting Blue light flashes (1s...
  • Page 11 RELOAD button RELOAD button: • Long press the button for 10s to switch the SEC1000 from dynamic IP mode to static IP mode. The indicator lights up from right to left after switching the mode. • Long press the button for 3s to switch the SEC1000 from static IP mode to dynamic IP mode.
  • Page 12: Main Functions Of Sec1000

    (2)If the user has a static IP, it is necessary to switch SEC1000 to the static IP mode. That is, press the Reload key for about 10 seconds to reset and restart SEC1000, About 10 seconds after pressing the Reload button, the LED lights on the SEC1000 internal Ezlogger Pro Panel will blink from right to left and reset and restart.
  • Page 13: Sec1000 Backflow Prevention Function

    4.3 SEC1000 Backflow Prevention Function Firstly, set the Total Capacity, Power Limit and the Ratio of CT( of external CT) , and then check the Export Enable (as shown in the figure below), so that the active voltage, current and...
  • Page 14: Technology Parameter

    5 Technology parameter Model SEC1000 (Smart Energy Controller 1000) Communication Max. Inverters Supported RS485 interface 1*RJ45, 10/100 Mbps Ethernet Configuration Ezlogger*1 Datalogger GM3000*1 Meter 100–280Vac, 50/60 Hz Power Supply ≤10 Power Consumption (W) Mechanical 350*460*143 Dimensions (W×H×D mm) Weight (kg)
  • Page 15 GoodWe Website GoodWe Technologies Co., Ltd. No. 90 Zijin Rd., New District, Suzhou, 215011, China www.goodwe.com service@goodwe.com Local Contacts 340-00713-01...