Goodwe SEC1000 User Manual

Goodwe SEC1000 User Manual

Smart energy controller
Hide thumbs Also See for SEC1000:

Advertisement

Quick Links

User Manual
Smart Energy Controller
SEC1000
V1.0-2022-01-30

Advertisement

loading
Need help?

Need help?

Do you have a question about the SEC1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goodwe SEC1000

  • Page 1 User Manual Smart Energy Controller SEC1000 V1.0-2022-01-30...
  • Page 2: Troubleshooting

    1 Symbols 2 Safety and Warning 3 Mounting 3.1 Mounting Instruction 3.2 Overview and Packaging 3.3 Inverter Installation 4 Troubleshooting 5 Technology parameter 6 Relevant Certification...
  • Page 3: Safety And Warning

    SEC1000. Otherwise, GoodWe will not assume the responsibility and quality assurance for the personal harm. • Make sure that the AC input voltage and input current match the rated voltage and current of SEC1000, otherwise the components will be damaged or cannot work properly,and GoodWe will not assume the responsibility and quality assurance for this case.
  • Page 4: Mounting Instruction

    3 Mounting 3.1 Mounting Instruction • SEC1000 must be installed where there is no significant shaking, shock vibration and no direct rain or snow. • SEC1000 shall be installed at eye level for easy operation and maintenance. • SEC1000 shoud not be installed near inflammable and explosive items.Any strong electro-magnetic equipment should be kept away from installation site.
  • Page 5 • The installation location must be well ventilated • SEC1000 can be placed horizontally or installed vertically • The SEC1000 must be installed vertical or with a backward tilt less 15°.No sidwways tilt is allowed.The connection area must point downwards.Refer to Figure 3.3.1-1.
  • Page 6 (2)Fix the wall mounting bracket on the wall with expansion bolts in accessory bag,refer to Figure 3.3.3-2 Expansion screw tube Back hang Tapping screw Hole size Figure3.3.2-2 Figure3.3.2-1 (3)Place SEC1000 on the wall-mounted bracket as illustrated in figure 3.3.2-3 Figure3.3.2-3...
  • Page 7 1. SEC1000 can be placed horizontally to work, as shown in the figure 3.3.2-4. 2. SEC1000 should be placed in a fixed place indoors as shown in the figure3.3.2-5. Figure3.3.2-5 Figure3.3.2-4 3.3.3 Port and wiring instructions ① Voltage Input Port(L1\L2\L3\N\PE) Input phase voltage range:...
  • Page 8 ④ LAN Network port LAN SEC1000 uses this port when accessing a network cable;The access point is as shown in the "NET" position in the figure above. It is recommended to use network cables better than Super Five Type. After wiring, use the fire-proof mud to seal the port, to ensure its protective performance.
  • Page 9 (2)If the user has a static IP, it is necessary to switch SEC1000 to the static IP mode. That is, press the Reload key for about 10 seconds to reset and restart SEC1000, About 10 seconds after pressing the Reload button, the LED lights on the SEC1000 internal Ezlogger Pro Panel will blink from right to left and reset and restart.
  • Page 10 Note: The RealTime Data configuration is supported only when the DERD & ARCB Setting is on. Otherwise, the configuration is not displayed. 3.3.5.1 SEC1000 Backflow Prevention Function Firstly, set the Total Capacity, Power Limit and the Ratio of CT( of external CT) , and then check the Export Enable (as shown in the figure below), so that the active voltage, current and power data can be monitored in real time.
  • Page 11 3.3.5.2 SEC1000 Reactive Power Compensation Function Set the variable ratio of external CT (note that the primary current value of external CT does not exceed 5000A, and the corresponding secondary current value does not exceed 5A). Set the desired Power Factor value.
  • Page 12 5 Technology parameter Name SEC1000 ( Smart Energy Controller 1000) Technology parameter Input voltage range Phase voltage: AC60V~280V Input voltage frecrency 50Hz/60Hz Input current range 0~5A Rated power consumption <10W Communication with the inverter RS485 Maximum distance from the inverter 1000m (use shielded twisted-pair cable)...
  • Page 13 GoodWe Website GoodWe Technologies Co., Ltd. No. 90 Zijin Rd., New District, Suzhou, 215011, China www.goodwe.com service@goodwe.com Local Contacts 340-00713-00...