Goodwe SEC1000S User Manual

Goodwe SEC1000S User Manual

Smart energy controller
Hide thumbs Also See for SEC1000S:

Advertisement

Quick Links

SEC1000S USER MANUAL
Smart Energy Controller

Advertisement

loading
Need help?

Need help?

Do you have a question about the SEC1000S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goodwe SEC1000S

  • Page 1 SEC1000S USER MANUAL Smart Energy Controller...
  • Page 2: Troubleshooting

    1 Symbols 2 Safety and Warning 3 Mounting 3.1 Mounting Instruction 3.2 Overview and Packaging 3.3 Inverter Installation 4 Troubleshooting 5 Technology parameter 6 Relevant Certification...
  • Page 3: Safety And Warning

    • To avoid electric shock,make sure the connection between SEC1000S and AC output of inverter. SEC1000S and Grid, is disconnected before performing any installation or maintenance. • When in operation,users should not touch any of the electrical parts of SEC1000S ,like internal components.cables, to avoid electic shock.
  • Page 4: Mounting Instruction

    • SEC1000S shoud not be installed near inflammable and explosive items.Any strong electro- magnetic equipment should be kept away from installation site. • SEC1000S shall be installed at a location free from explosive hazardous media and free from gas and dust sufficient to corrode metals and destroy insulation.
  • Page 5 • The installation location must be well ventilated. • SEC1000S can be placed horizontally or installed vertically. • The SEC1000S must be installed vertical or with a backward tilt less 15°.No sidwways tilt is allowed.The connection area must point downwards.Refer to Figure 3.3.1-1.
  • Page 6 (2)Fix the wall mounting bracket on the wall with expansion bolts in accessory bag,refer to Figure 3.3.3-2. Expansion screw tube Back hang Tapping screw Hole size Figure3.3.2-2 Figure3.3.2-1 (3)Place SEC1000S on the wall-mounted bracket as illustrated in figure 3.3.2-3. Figure3.3.2-3...
  • Page 7 1. SEC1000S can be placed horizontally to work, as shown in the figure 3.3.2-4. 2. SEC1000S should be placed in a fixed place indoors as shown in the figure 3.3.2-5. Figure3.3.2-5 Figure3.3.2-4 3.3.3 Port and wiring instructions ① Voltage Input Port(L1\L2\L3\N\PE) Input phase voltage range:...
  • Page 8 ④ LAN Network port LAN SEC1000S uses this port when accessing a network cable;The access point is as shown in the "NET" position in the figure above. It is recommended to use network cables better than Super Five Type. After wiring, use the fire- proof mud to seal the port, to ensure its protective performance.
  • Page 9 CT connected cable Note: No separate Smart Meter is required in inverter paralleling system along with SEC1000S deployed. This solution is only applicable to the paralleling of on-grid side not to back-up side. There are special requirements on the version of firmware of ET or BT applied in this solution, with DSP version 01 or newer and ARM version 09 or newer.
  • Page 10 Router LAN port with the network cable to connect to the network, namely plug and play. (2)If the user has a static IP, it is necessary to switch SEC1000S to the static IP mode. That is, press the Reload key for about 10 seconds to reset and restart SEC1000S, About 10 seconds after pressing the Reload button, the LED lights on the SEC1000S internal EzLogger Pro Panel will blink from right to left and reset and restart.
  • Page 11 10 if there are 10 inverters in the paralleling system. The ID of inverter connected to the communication port should not be duplicate. To monitoring the whole system, all inverters should be registered under the same power plant on GoodWe monitoring platform SEMS Portal.
  • Page 12 B+ and B- cable Note: When replacing the meter, all 3 groups of CTs need to be short-circuited. 5 Technology parameter Name SEC1000S (Smart Energy Controller 1000S) Technology parameter Phase voltage: AC60V~280V Input voltage range Line voltage: AC100V~480V Input voltage frecrency...
  • Page 13 GoodWe(Australia) GoodWe(China) service.au@goodwe.com.cn No.90 Zijin Rd., New Distric www.goodwe.com.cn Suzhou, 215011, China T: 400 998 1212 service.chn@goodwe.com.cn www.goodwe.com.cn GoodWe(Netherlands) GoodWe(UK) service.nl@goodwe.com.cn enquiries@goodwe.co.uk www.goodwe.com.cn www.goodwe.co.uk Note: The information above is subject to change without prior notice,details refer to www.goodwe.com.cn.