Hitachi RAS-10XH1 Service Manual page 103

Table of Contents

Advertisement

2.Failure phenomenon: The product will not receive a remote control signal.
[ Situation ]   The product does not receive a remote control signal. It is not very responsive.
(The product does run normally in response to the emergency operation switch.)
[ Estimated failure
locations ]
[ Cautions ]
Diagnosis flow
[
]
Initiating troubleshooting
Does the remote control unit have a sufficient battery capacity?
Did you identify a failure phenomenon?
Conduct an operation check according to "checking the remote
control" (page 142).
Is the remote control normal?
Yes
Press the reset switch of the remote control unit,
then conduct another operation check.
Has the product worked?
Check for jamming due to an external factor while referring to
"how to identify sources of jamming in the reception of
remote control signals" (page 121).
Is there jamming from outside?
Is the CN16 securely connected?
Replace the "display board."
[
Cautions in replacing the display board
 
・ Remote control failure, remote control low battery level, remote control poorly set
・ Remote control light-receiving unit
・ Connector loose, wire break
・ Normal product (external factors: the remote control units for lighting equipment and other
equipment, electrical noise, etc.)
・ Even if the product is trouble-free, a factor coming from outside the product may hamper the
reception of signals from the remote control unit.
・ Batteries may decline in capacity at low temperatures. Old batteries decline particularly much in
voltage in the morning and evening of winter, resulting in the poor arrival of remote control signals.
Instruct your users to use new alkaline batteries.
Yes
Yes
No
No
Yes
]  
Be sure to replace the indicating P.W.B. components.
No
If the liquid crystal display becomes
extremely faded when a remote control
signal is sent, replace the batteries.
No
Go on to "how to identify sources of
jamming in the reception of remote
control signals" (page 121).
Yes
Instruct your users to be sure to press
the reset switch after replacing the
batteries.
No
Replace the "remote control unit."
Yes
Cope with jamming according to its cause.
No
Reconnect the connector correctly.
– 120 –
 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-10xh1Ras-14xh1Rac-14xh1