Operator Controls; Reset Caused By Line Voltage Reduction - HP 9895A Service Manual

Flexible disc memory
Hide thumbs Also See for 9895A:
Table of Contents

Advertisement

1-16
General Information
Operator Controls
There are no operator controls on the 9895A Disc Memory.
Reset Caused
by
Line Voltage Reduction
If the 9895A experiences a momentary line voltage reduction, or sag, it may lose data bits
during a transfer while appearing to operate properly. In order to prevent this situation, the
9895A will go into a Reset mode if a sag of roughly 30% from nominal for about half a
second occurs. This warns the operator that data bits may have been lost, so that this
condition can be checked for and remedied immediately. There are two ways of recovering
from the Reset condition. The power switch may be turned off and then turned back on, or
the reset switch on the controller board may be pressed (it is the right-hand switch on the
front edge of the controller board).