APT 750CM Instruction Manual

Tft lcd display

Advertisement

Quick Links

Product:
APT Model:
Client Model:
Client:
Client Check:
Supplier:
Email
Approval:
Specification
March 2023
TFT LCD Display
750CM
APT(Tianjin) Development Co., Ltd.
1001, Building 5 HuaDing, No.1 HuaKe 3
Road,
Development Zone, Tianjin, China
TEL: 86 22 26345859
FAX: 86 22 83719955
yzhao@aptdevelop.com
Binhai
hi-tech
Industrial

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 750CM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for APT 750CM

  • Page 1 Product: TFT LCD Display APT Model: 750CM Client Model: Client: Client Check: Supplier: APT(Tianjin) Development Co., Ltd. 1001, Building 5 HuaDing, No.1 HuaKe 3 Road, Binhai hi-tech Industrial Development Zone, Tianjin, China TEL: 86 22 26345859 FAX: 86 22 83719955 Email yzhao@aptdevelop.com...
  • Page 2: Table Of Contents

    APT (Tianjin) Development Co., Ltd. Content Product model ............................3 Suppliers ..............................3 Specifications ............................3 Dimensions and Material ........................3 Features ..............................4 Main page ............................4 Functional Description .......................... 5 Power on/off ..........................5 Assist level ..........................5 Speed &...
  • Page 3 APT (Tianjin) Development Co., Ltd. Install and use precautions ......................19 Copyright Notice .......................... 19 2 / 19...
  • Page 4: Product Model

    APT (Tianjin) Development Co., Ltd. 1 Product model Model: 750CM 2 Suppliers APT (Tianjin) Development Co., Ltd. 3 Specifications  3.2inch TFT screen(480*RGB*320)  Wide-voltage range: Low voltage: 20~70V High voltage: 20~90V  Multi-language support(6 languages)  Rated operating current : 40mA, Maximum output current to controller: 100mA、...
  • Page 5: Features

    APT (Tianjin) Development Co., Ltd. 5 Features  3.2inch TFT screen  6 languages: Czech, German, French, English, Italian, Spanish are supported.  Independent button, easy to operate  Speed indicator:Speed (Real-time), AVG Speed, MAX Speed  Metric / Imperial ...
  • Page 6: Functional Description

    APT (Tianjin) Development Co., Ltd. affected when the driving speed exceeds the maximum indication.  Mileage Mode: Odometer, Trip distance, Range (if battery support), Riding time  Smart battery Power indicator: Provide a reliable battery Power indicator.  Assist Level: 4 modes optional (3/5/9/U) ...
  • Page 7: Speed & Mileage Mode

    APT (Tianjin) Development Co., Ltd. 7.3 Speed & Mileage mode Click MENU button can change the speed mode, RT Speed->AVG Speed->MAX Speed. Speed Mode * At MAX SPD or AVG SPD, If there is no operation for 5 seconds, right item will restore to RT Speed automatically.
  • Page 8: Data Cleanup

    APT (Tianjin) Development Co., Ltd. Walking Mode 7.6 Data cleanup Press and hold UP & DOWN button together for 1 second can clean temporary data (TRIP, Riding-Time, AVG SPD, MAX SPD data). * Temporary data is automatically saved when power off. Abnormal power outage will cause data lost.
  • Page 9: Language

    APT (Tianjin) Development Co., Ltd. 8.1.1 Language 6 languages are supported:Czech, German, French, English, Italian, Spanish. Default is English. Select language then click “Back” to confirm. Language 8.1.2 System Select Metric or Imperial. Metric and Imperial 8.1.3 Brightness Press UP/DOWN button to change brightness of backlight, 1 is darkness, 5 is brightness.
  • Page 10: Auto Off

    APT (Tianjin) Development Co., Ltd. The light is turned on Display setting The light is turned off 8.1.4 Auto off This item enables to set the automatic shutdown time of the display, from 1 to 10min. Default value is 5 minutes, represents display shut down when there was no operation and riding for 5 minutes.
  • Page 11: Clock

    APT (Tianjin) Development Co., Ltd. 8.1.6 Clock This item set date and time. You can choose Show-12 hour, Show-24 hour or hide Clock on Main Page through UP/DOWN button. Show-12 hour Show-24 hour Hide * Note: When display was powered off, internal Button Battery can keep clock running. When display is power on, Button Battery will be charged by external battery.
  • Page 12: Assist Levels

    APT (Tianjin) Development Co., Ltd. If you had set start password ON, you must input right password before power on. Turn on the start password function Start password setting page You need to input the right password before start with 30 seconds.
  • Page 13: Wheel

    APT (Tianjin) Development Co., Ltd. 8.2.3 Wheel This item can select wheel diameter, including 16/18/20/22/24/26/27/27.5/28/29 inch. Incorrect wheel diameter selection can lead to abnormal speeds. 8.2.4 Battery The following voltage settings are supported: Low voltage: 24V/36V/48V/52V High voltage: 48V/52V/60V/72V 8.2.5 Battery Ind This item can select battery Ind setting, including OFF/Percent/Voltage.
  • Page 14: Pow Ind

    APT (Tianjin) Development Co., Ltd. Voltage Percent Note: The voltage is the remaining voltage or percentage of the battery. 8.2.6 Pow Ind This item can select power indicator on Main Page, ‘OFF’, ‘Power(W)’ and ‘Current(A)’. Output power (W) Output current (A) Power (OFF) Note: Power indicator represent battery’s output power (current), not motor.
  • Page 15: Speed Limit

    APT (Tianjin) Development Co., Ltd. 8.3.1 Speed Limit Select range 10km/h ~ 41km/h(6.2Mile/h ~ 25.4Mile/h). 8.3.2 Current Limit Select range 1~50A. 8.3.3 Poles In motor Magnetic poles inside the motor, select range 1~15. 14 / 19...
  • Page 16: Start After Poles

    APT (Tianjin) Development Co., Ltd. 8.3.4 Start after poles How many poles (speed sensor) need to be detected by controller before starting motor, select range 1~15. 8.3.5 Clockwise Start This parameter represent speed sensor turn direction, support front or reverse.
  • Page 17: Start Mode

    APT (Tianjin) Development Co., Ltd. 8.3.8 Start mode Support Three modes of STD/Eco/Pow. Pow mode means use maximum current when speed up, Eco mode means use minimum current. 8.4 Factory Setting Select ‘YES’ will restore all setting to factory defaults.
  • Page 18: Product Information

    APT (Tianjin) Development Co., Ltd. 8.5.1 Product Information Product Information show Hardware Version, Software Version, Date. Product information 8.5.2 Battery Information Battery Information can show Voltage, Capacity, Cycle times, Current, Last Un- charge Times, Temperature, Remaining Capacity, Full Charge Capacity, Max Un- charge Times.
  • Page 19: Assembly Instructions

    APT (Tianjin) Development Co., Ltd. Error code prompt page Error Code Error description Handle Current abnormality Check the controller Throttle error Check throttle and connection three-phase power error Check three-phase power line connection Hall sensor error Check the hall connection...
  • Page 20 12 Copyright Notice Questions about your e-bike, please contact with dealer firstly. APT reserves the right to modify this specification file,without declaration in advance. Content and Image owner:APT (Tianjin) Development Co., Ltd. 1001, Building 5 HuaDing, No.1 HuaKe 3 Road, Binhai hi-tech Industrial Development Zone, Tianjin, China website:www.aptdevelop.com...