Video Content Analysis (Vca); Audio Alarm - Bosch DINION 7100i IR NBE-7702-ALX User Manual

Hide thumbs Also See for DINION 7100i IR NBE-7702-ALX:
Table of Contents

Advertisement

DINION 7100i IR
Note:
In the event of an alarm, a larger network bandwidth is sometimes required for additional
video streams (if multicast operation is not possible).
Stream
Select a stream to be transmitted.
Remote port
Select an appropriate browser port depending on the network configuration.
The ports for HTTPS connections are only available if SSL encryption is set to On.
Video output
If a hardware receiver is used, select the analog video output to which the signal should be
switched. If the destination device is unknown, select First available. This places the image on
the first video output with no signal.
The connected monitor only displays images when an alarm is triggered.
Note:
Refer to the destination unit documentation for more information on image display options
and available video outputs.
Decoder
If a split image is set for the selected video output, select a decoder to display the alarm
image. The decoder selected determines the position in the split image.
SSL encryption
SSL encryption protects data used for establishing a connection, such as the password. By
selecting On, only encrypted ports are available for the Remote port parameter. SSL
encryption must be activated and configured on both sides of a connection.
The appropriate certificates must also have been uploaded. (Certificates can be uploaded on
the Certificates page.)
Configure and activate encryption for media data (such as video, metadata or audio when
available) on the Encryption page (encryption is only available if the appropriate license is
installed).
Audio
Select On to transmit the audio stream with an alarm connection.
Click Set to apply the changes.
4.6.2

Video Content Analysis (VCA)

This device has an integrated video analytics suite of AI-driven software, which detects and
analyzes changes in the picture using image processing algorithms. Such changes can be due
to movements in the device's field of view. Detection of movement can be used to trigger an
alarm and to transmit metadata.
Various VCA configurations can be selected and adapted to your application, as required.
Configure the VCA setting in the Bosch Configuration Manager.
4.6.3

Audio Alarm

Alarms can be generated based on audio signals. Configure signal strengths and frequency
ranges so that false alarms, for example, machine noise or background noise, are avoided.
Set up normal audio transmission before configuring the audio alarm.
Audio alarm
Select On for the device to generate audio alarms.
Bosch Security Systems B.V.