Technibel Climatisation GRV180C5TA Technical Data & Service Manual

Hide thumbs Also See for GRV180C5TA:

Advertisement

Quick Links

TECHNICAL DATA
& SERVICE MANUAL
OUTDOOR UNIT: GRV180C5TA-
SPLIT SYSTEM AIR CONDITIONER
Model No.
GRV180C5TA-
GRV180C5TAB-
GRV180L5TA-
GRV180L5TAB-
All manuals and user guides at all-guides.com
GRV180C5TAB-
GRV180L5TA-
GRV180L5TAB-
GRV220C5TA-
Product Code No.
387107059
387107068
387107060
387107069
GRV220C5TA-
0.8180.268.1
Model No.
09/2004
Product Code No.
387107062

Advertisement

Table of Contents
loading

Summary of Contents for Technibel Climatisation GRV180C5TA

  • Page 1 All manuals and user guides at all-guides.com TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRV180C5TA- GRV180C5TAB- GRV180L5TA- GRV180L5TAB- GRV220C5TA- SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRV180C5TA- 387107059 GRV180C5TAB- 387107068 GRV180L5TA- 387107060 GRV180L5TAB- 387107069 Model No. Product Code No.
  • Page 2 All manuals and user guides at all-guides.com IMPORTANT! • Ground the unit following local electrical codes. Please read before installation • The Yellow/Green wire cannot be used for any connection different from the ground connection. • Connect all wiring tightly. Loose wiring may cause overheating This air conditioning system meets strict safety and operating at connection points and a possible fire hazard.
  • Page 3: Table Of Contents

    All manuals and user guides at all-guides.com Table of Contents Page 1. OPERATING RANGE 2. SPECIFICATIONS 2-1 Unit specifications 2-2 Major Component specifications 2-3 Other Component specifications 3. DIMENSIONAL DATA 4. REFRIGERANT FLOW DIAGRAM 5. PERFORMANCE DATA 5-1 Performance Charts 5-2 Cooling Capacity 6.
  • Page 4: Operating Range

    All manuals and user guides at all-guides.com 1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 32°C D.B. / 23°C W.B. 43°C D.B. Cooling (*)19°C D.B. Minimum 19°C D.B. / 14°C W.B. (*) SCL MODEL : -15°C D.B.
  • Page 5: Specifications

    All manuals and user guides at all-guides.com 2. SPECIFICATIONS 2-1 Unit Specifications GRV180C5TA- 220 - 240V ~ 50Hz Power source 230V Voltage rating Cooling Performance * MCAV180C5VA- 5,00 Capacity BTU/h 17063 Air circulation (High) m³/h Moisture removal (High) Liters/h Electrical Rating...
  • Page 6 All manuals and user guides at all-guides.com GRV180C5TAB- 220 - 240V ~ 50Hz Power source 230V Voltage rating Cooling Performance * MCAV180C5VA- 5,00 Capacity BTU/h 17063 Air circulation (High) m³/h Moisture removal (High) Liters/h Electrical Rating Cooling 198 ~ 264 Available voltage range 10,50 Running amperes...
  • Page 7 All manuals and user guides at all-guides.com GRV180L5TA- Power source 220 - 240V ~ 50Hz Voltage rating 230V Cooling Performance * MCAV180C5VA- 5,00 Capacity 17063 BTU/h Air circulation (High) m³/h Moisture removal (High) Liters/h Cooling Electrical Rating 198 ~ 264 Available voltage range 10,00 Running amperes...
  • Page 8 All manuals and user guides at all-guides.com GRV180L5TAB- Power source 220 - 240V ~ 50Hz Voltage rating 230V Cooling Performance * MCAV180C5VA- 5,00 Capacity 17063 BTU/h Air circulation (High) m³/h Moisture removal (High) Liters/h Cooling Electrical Rating 198 ~ 264 Available voltage range 10,50 Running amperes...
  • Page 9 All manuals and user guides at all-guides.com GRV220C5TA- Power source 220 - 240V ~ 50Hz Voltage rating 230V Cooling Performance * MCAV220C5VA- 5,90 Capacity 20134 BTU/h Air circulation (High) m³/h Moisture removal (High) Liters/h Cooling Electrical Rating 198 ~ 264 Available voltage range 13,00 Running amperes...
  • Page 10: Major Component Specifications

    All manuals and user guides at all-guides.com 2-2 Major Component Specifications Outdoor Unit: GRV180C5TA- Compressor Type Rotary (Hermetic) Compressor model 80807045B C-2RN170H5W 1700 Nominal output FV68S…800 Compressor oil…Amount Ω C-R: 1,353 Coil resistance (Ambient temp. 25°C) C-S: 3,422 Internal protector...
  • Page 11 All manuals and user guides at all-guides.com Outdoor Unit: GRV180C5TAB- Compressor Type Rotary (Hermetic) Compressor model 4JS350EAA( JSM671 - 48 ) 1700 Nominal output RB68A or FREOL ALPHA68M 700 Compressor oil…Amount Ω C-R: 0,957 Coil resistance (Ambient temp. 20°C) Ω C-S: 3,617 Internal protector Safety devices...
  • Page 12 All manuals and user guides at all-guides.com Outdoor Unit: GRV180L5TA- Compressor Type Rotary (Hermetic) Compressor model 80807045B C-2RN170H5W 1700 Nominal output FV68S…800 Compressor oil…Amount Ω C-R: 1,353 Coil resistance (Ambient temp. 25°C) Ω C-S: 3,422 Internal protector Safety devices Type Overload relay Automatic opening Operating Temp.
  • Page 13 All manuals and user guides at all-guides.com Outdoor Unit: GRV180L5TAB- Controller PCB Johnson Control Compressor Rotary (Hermetic) Type 4JS350EAA( JSM671 - 48 ) Compressor model 1700 Nominal output RB68A or FREOL ALPHA68M 700 Compressor oil…Amount Ω C-R: 0,957 Coil resistance (Ambient temp. 20°C) Ω...
  • Page 14 All manuals and user guides at all-guides.com Outdoor Unit: GRV220C5TA- Compressor Type Rotary (Hermetic) Compressor model 80244035 C-RN220H5A 2200 Nominal output FV68S…1350 Compressor oil…Amount Ω C-R: 0,777 Coil resistance (Ambient temp. 25°C) Ω C-S: 2,408 Internal protector External protector Safety devices Type OL-D24 Overload relay...
  • Page 15: Other Component Specifications

    All manuals and user guides at all-guides.com 2-3 Other Component Specifications Outdoor Unit: GRV180C5TA- GRV180C5TAB- GRV180L5TA- GRV180L5TAB- Power Relay Type G7L-2A-TUB AC 200-240 V ~ 50/60 Hz Coil Rating 21 ± 15% Coil resistance (at 23°C) kΩ AC 220 V , 25 A...
  • Page 16 All manuals and user guides at all-guides.com Outdoor Unit: GRV220C5TA- Thermostat (Fan Speed Control 23S) YTB-S383 Type Switching Temp. °C high 28.5 ± 1 °C HIGH 31 ± 1 Magnetic Contactor (MG) Type HE-20FT31B or CLK-20J-S20A Coil Rating AC 220-240 V ~ 50 HAC 220-240 V ~ 50 Hz Ω...
  • Page 17: Dimensional Data

    All manuals and user guides at all-guides.com 3. DIMENSIONAL DATA GRV180C5TA- Outdoor Unit: GRV180C5TAB- GRV180L5TA- GRV180L5TAB- Air intake 4 – ø12 holes Air discharge Wide tube service valve ø12.7 (1/2") Narrow tube service valve ø6.35 (1/4") Unit : mm...
  • Page 18 All manuals and user guides at all-guides.com GRV220C5TA- Outdoor Unit: Air intake Air discharge Wide tube service valve ø15.88 (5/8") Narrow tube service valve ø6.35 (1/4") 6 – ø3.1 holes Check port ø6.35 (1/4") Unit : mm...
  • Page 19: Refrigerant Flow Diagram

    All manuals and user guides at all-guides.com 4. REFRIGERANT FLOW DIAGRAM Indoor Unit: Outdoor Unit: GRV180C5TA- Indoor Unit: Outdoor Unit: GRV180C5TAB-...
  • Page 20 All manuals and user guides at all-guides.com Indoor Unit: Outdoor Unit: GRV180L5TA- Indoor Unit: Outdoor Unit: GRV180L5TAB-...
  • Page 21 All manuals and user guides at all-guides.com Indoor Unit: Outdoor Unit: GRV220C5TA-...
  • Page 22: Performance Data

    All manuals and user guides at all-guides.com 5. PERFORMANCE DATA 5-1 Performance charts GRV180C5TA- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) 0,60 Indoor inlet air D.B. (°C) 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
  • Page 23 All manuals and user guides at all-guides.com GRV180C5TAB- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) 0,60 Indoor inlet air D.B. (°C) 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
  • Page 24 All manuals and user guides at all-guides.com GRV180L5TA- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) Indoor inlet air D.B. (°C) 0,60 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
  • Page 25 All manuals and user guides at all-guides.com GRV180L5TAB- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) Indoor inlet air D.B. (°C) 0,60 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
  • Page 26 All manuals and user guides at all-guides.com GRV220C5TA- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) Indoor inlet air D.B. (°C) 0,60 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
  • Page 27: Cooling Capacity

    All manuals and user guides at all-guides.com 5-2 Cooling Capacity GRV180C5TA- OUTDOOR UNIT: MCAV180C5VA- INDOOR UNIT: 220 - 240V ~ 50Hz RATING CAPACITY 5,00 kW moisture removal 2,3 l/h COMP. POWER INPUT 2,044 kW max comp input 2,494 kW AIR FLOW RATE 760 m³/h...
  • Page 28 All manuals and user guides at all-guides.com GRV180C5TAB- OUTDOOR UNIT: MCAV180C5VA- INDOOR UNIT: 220 - 240V ~ 50Hz RATING CAPACITY 5,00 kW moisture removal 2,3 l/h COMP. POWER INPUT 2,097 kW max comp input 2,497 kW AIR FLOW RATE 760 m³/h EVAPORATOR CONDENSER ENT.TEMP.
  • Page 29 All manuals and user guides at all-guides.com GRV180L5TA- OUTDOOR UNIT: MCAV180C5VA- INDOOR UNIT: 220 - 240V ~ 50Hz RATING CAPACITY 5,00 kW moisture removal 2,3 l/h COMP. POWER INPUT 2,043 kW max comp input 2,493 kW AIR FLOW RATE 760 m³/h EVAPORATOR CONDENSER ENT.TEMP.
  • Page 30 All manuals and user guides at all-guides.com GRV180L5TAB- OUTDOOR UNIT: MCAV180C5VA- INDOOR UNIT: 220 - 240V ~ 50Hz RATING CAPACITY 5,00 kW moisture removal 2,3 l/h COMP. POWER INPUT 2,097 kW max comp input 2,497 kW AIR FLOW RATE 760 m³/h EVAPORATOR CONDENSER ENT.TEMP.
  • Page 31 All manuals and user guides at all-guides.com GRV220C5TA- OUTDOOR UNIT: MCAV220C5VA- INDOOR UNIT: 220 - 240V ~ 50Hz RATING CAPACITY 5,90 kW moisture removal 3,3 l/h COMP. POWER INPUT 2,551 kW max comp input 3,101 kW AIR FLOW RATE 830 m³/h EVAPORATOR CONDENSER ENT.TEMP.
  • Page 32: Electrical Data

    All manuals and user guides at all-guides.com 6. ELECTRICAL DATA 6-1 Electrical characteristics OUTDOOR UNIT: GRV180C5TA- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,40...
  • Page 33 All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV180C5TAB- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,44 10,5 Power input 0,070 0,083 2,097 2,250 Full load conditions Running Amps.
  • Page 34 All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV180L5TA- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,41 10,0 Power input 0,070 0,087 2,043 2,200 Full load conditions Running Amps.
  • Page 35 All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV180L5TAB- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,44 10,5 Power input 0,070 0,083 2,097 2,250 Full load conditions Running Amps.
  • Page 36 All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV220C5TA- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,39 0,55 12,1 13,0 Power input 0,075 0,124 2,551 2,750 Full load conditions...
  • Page 37: Electric Wiring Diagram

    All manuals and user guides at all-guides.com GRV180C5TA- 6-2 Electric Wiring Diagram GRV180C5TAB- OUTDOOR UNIT: GRV180L5TA- OUTDOOR UNIT:...
  • Page 38 All manuals and user guides at all-guides.com GRV220C5TA- OUTDOOR UNIT:...
  • Page 39: System Wiring Diagram

    All manuals and user guides at all-guides.com 6-3 System Wiring Diagram...
  • Page 40 All manuals and user guides at all-guides.com R.D. 28 Reyrieux BP 131 - 01601 Trévoux CEDEX France Tél. 04.74.00.92.92 - Fax 04.74.00.42.00 R.C.S. Bourg-en-Bresse B 759 200 728...