Summary of Contents for Technibel Climatisation GRV180C5TA
Page 1
All manuals and user guides at all-guides.com TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRV180C5TA- GRV180C5TAB- GRV180L5TA- GRV180L5TAB- GRV220C5TA- SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRV180C5TA- 387107059 GRV180C5TAB- 387107068 GRV180L5TA- 387107060 GRV180L5TAB- 387107069 Model No. Product Code No.
Page 2
All manuals and user guides at all-guides.com IMPORTANT! • Ground the unit following local electrical codes. Please read before installation • The Yellow/Green wire cannot be used for any connection different from the ground connection. • Connect all wiring tightly. Loose wiring may cause overheating This air conditioning system meets strict safety and operating at connection points and a possible fire hazard.
All manuals and user guides at all-guides.com Table of Contents Page 1. OPERATING RANGE 2. SPECIFICATIONS 2-1 Unit specifications 2-2 Major Component specifications 2-3 Other Component specifications 3. DIMENSIONAL DATA 4. REFRIGERANT FLOW DIAGRAM 5. PERFORMANCE DATA 5-1 Performance Charts 5-2 Cooling Capacity 6.
All manuals and user guides at all-guides.com 1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 32°C D.B. / 23°C W.B. 43°C D.B. Cooling (*)19°C D.B. Minimum 19°C D.B. / 14°C W.B. (*) SCL MODEL : -15°C D.B.
All manuals and user guides at all-guides.com 2. SPECIFICATIONS 2-1 Unit Specifications GRV180C5TA- 220 - 240V ~ 50Hz Power source 230V Voltage rating Cooling Performance * MCAV180C5VA- 5,00 Capacity BTU/h 17063 Air circulation (High) m³/h Moisture removal (High) Liters/h Electrical Rating...
Page 6
All manuals and user guides at all-guides.com GRV180C5TAB- 220 - 240V ~ 50Hz Power source 230V Voltage rating Cooling Performance * MCAV180C5VA- 5,00 Capacity BTU/h 17063 Air circulation (High) m³/h Moisture removal (High) Liters/h Electrical Rating Cooling 198 ~ 264 Available voltage range 10,50 Running amperes...
Page 7
All manuals and user guides at all-guides.com GRV180L5TA- Power source 220 - 240V ~ 50Hz Voltage rating 230V Cooling Performance * MCAV180C5VA- 5,00 Capacity 17063 BTU/h Air circulation (High) m³/h Moisture removal (High) Liters/h Cooling Electrical Rating 198 ~ 264 Available voltage range 10,00 Running amperes...
Page 8
All manuals and user guides at all-guides.com GRV180L5TAB- Power source 220 - 240V ~ 50Hz Voltage rating 230V Cooling Performance * MCAV180C5VA- 5,00 Capacity 17063 BTU/h Air circulation (High) m³/h Moisture removal (High) Liters/h Cooling Electrical Rating 198 ~ 264 Available voltage range 10,50 Running amperes...
Page 9
All manuals and user guides at all-guides.com GRV220C5TA- Power source 220 - 240V ~ 50Hz Voltage rating 230V Cooling Performance * MCAV220C5VA- 5,90 Capacity 20134 BTU/h Air circulation (High) m³/h Moisture removal (High) Liters/h Cooling Electrical Rating 198 ~ 264 Available voltage range 13,00 Running amperes...
All manuals and user guides at all-guides.com 2-3 Other Component Specifications Outdoor Unit: GRV180C5TA- GRV180C5TAB- GRV180L5TA- GRV180L5TAB- Power Relay Type G7L-2A-TUB AC 200-240 V ~ 50/60 Hz Coil Rating 21 ± 15% Coil resistance (at 23°C) kΩ AC 220 V , 25 A...
Page 16
All manuals and user guides at all-guides.com Outdoor Unit: GRV220C5TA- Thermostat (Fan Speed Control 23S) YTB-S383 Type Switching Temp. °C high 28.5 ± 1 °C HIGH 31 ± 1 Magnetic Contactor (MG) Type HE-20FT31B or CLK-20J-S20A Coil Rating AC 220-240 V ~ 50 HAC 220-240 V ~ 50 Hz Ω...
All manuals and user guides at all-guides.com 3. DIMENSIONAL DATA GRV180C5TA- Outdoor Unit: GRV180C5TAB- GRV180L5TA- GRV180L5TAB- Air intake 4 – ø12 holes Air discharge Wide tube service valve ø12.7 (1/2") Narrow tube service valve ø6.35 (1/4") Unit : mm...
Page 18
All manuals and user guides at all-guides.com GRV220C5TA- Outdoor Unit: Air intake Air discharge Wide tube service valve ø15.88 (5/8") Narrow tube service valve ø6.35 (1/4") 6 – ø3.1 holes Check port ø6.35 (1/4") Unit : mm...
All manuals and user guides at all-guides.com 5. PERFORMANCE DATA 5-1 Performance charts GRV180C5TA- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) 0,60 Indoor inlet air D.B. (°C) 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
Page 23
All manuals and user guides at all-guides.com GRV180C5TAB- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) 0,60 Indoor inlet air D.B. (°C) 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
Page 24
All manuals and user guides at all-guides.com GRV180L5TA- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) Indoor inlet air D.B. (°C) 0,60 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
Page 25
All manuals and user guides at all-guides.com GRV180L5TAB- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) Indoor inlet air D.B. (°C) 0,60 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
Page 26
All manuals and user guides at all-guides.com GRV220C5TA- Cooling Characteristics Indoor inlet air D.B. (°C) Outdoor inlet air D.B. temp. (°C) Indoor inlet air D.B. (°C) 0,60 0,50 0,40 0,30 0,20 0,10 0,00 Outdoor inlet air D.B. (°C) Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high values in heating mode.
All manuals and user guides at all-guides.com 6. ELECTRICAL DATA 6-1 Electrical characteristics OUTDOOR UNIT: GRV180C5TA- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,40...
Page 33
All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV180C5TAB- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,44 10,5 Power input 0,070 0,083 2,097 2,250 Full load conditions Running Amps.
Page 34
All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV180L5TA- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,41 10,0 Power input 0,070 0,087 2,043 2,200 Full load conditions Running Amps.
Page 35
All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV180L5TAB- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,37 0,44 10,5 Power input 0,070 0,083 2,097 2,250 Full load conditions Running Amps.
Page 36
All manuals and user guides at all-guides.com OUTDOOR UNIT: GRV220C5TA- COOLING Indoor Unit Complete Unit Outdoor unit Fan Motor Fan Motor Compressor performance at 230V 1-Phase 50 Hz Rating conditions Running Amps. 0,39 0,55 12,1 13,0 Power input 0,075 0,124 2,551 2,750 Full load conditions...
All manuals and user guides at all-guides.com 6-3 System Wiring Diagram...
Page 40
All manuals and user guides at all-guides.com R.D. 28 Reyrieux BP 131 - 01601 Trévoux CEDEX France Tél. 04.74.00.92.92 - Fax 04.74.00.42.00 R.C.S. Bourg-en-Bresse B 759 200 728...