Kenwood NXR-1800 Service Manual page 94

Uhf repeater
Hide thumbs Also See for NXR-1800:
Table of Contents

Advertisement

Error Information
Web Tool
OLED Display
(Error Code)
E102
HSB LAN Error
E103
Beacon Error
E201
Fan Error
E202
PWR Sup Error
E204
RX PLL Unlock
E205
TX PLL Unlock
E206
HPA Error
E207
Drive Temp Error Temperature
E208
TX Temp Error
E209
TCXO Temp
Error
E210
HPA Temp Error Temperature
E211
IF IC Error
* If any of E207, E208, or E210 occurs before or during the transmission, the repeater will transmit with the reduced transmit power
than normal. Even if all of these errors are cleared during in this transmission, the transmit power in this state is continued until the
end of this transmission.
1-94 (No.RA094<Rev.002>)
Error Event /
Item Name
Hot Standby LAN
The LAN connection between the Main and Sub repeaters under Hot Standby
Connection Error
fails.
This error will be displayed when the following cases.
Case1. Detection Error between the Main and Sub repeaters at the start up
process. This error is displayed to both repeaters in this case.
Case2. Detection Error of the standby repeater at the active repeater when the
hot standby works as normal. This error is displayed to the repeater that was
acting as the active repeater. Then the standby repeater will start working as the
active repeater.
Check the network connection, IP Address of Private IP and Virtual IP, or the
network equipment / port permission.
Beacon Sync
The sync signal from the Host Repeater (Primary) for Beacon fails under
Disconnect
Conventional IP Network.
This error is not applicable for the repeater working as the host itself.
The below is the case depends on the setting of Host Repeater.
Secondary: When starting as the host due to the primary repeater failure.
Deselected: When failing to receive the sync from the host (or the secondary)
Check the networking connection.
Fan Error
The pulse detection of the cooling fan rotation fails.
Check the cooling fan itself or the related circuit around it.
Power Supply
The power supply voltage is below than the voltage preconfigured in "Power
Voltage Error
Supply Lower Level" on FPU. The default value is "12.2V".
Check the power supply equipment or the FPU setting.
RX PLL Unlock
The circuit block of RX PLL may have a problem.
Proceed the general circuit troubleshooting as the receiver.
TX PLL Unlock
The circuit block of TX PLL may have a problem.
Proceed the general circuit troubleshooting as the transmitter.
Current
The current consumption of HPA (High Power Amp) is abnormal.
Consumption
There may be a possibility of an abnormality in VSWR, abnormality of the TX
(HPA) Error
block circuit (Drive Amp, High Power Amp), or abnormality of Fan action.
Proceed the general circuit troubleshooting.
The temperature of Drive Amp is abnormal (too high).
(Drive Amp) Error
There may be a possibility of excessive transmission continuation, abnormality
of the cooling fan action or an abnormality in the TX block circuit.
Temperature
The temperature of TX Block is abnormal (too high).
(TX Block) Error
There may be a possibility of excessive transmission continuation, abnormality
of the cooling fan action, or an abnormality in the TX block circuit.
Proceed the general circuit troubleshooting.
Temperature
The temperature of TCXO is abnormal (too high).
(TCXO) Error
There may be a possibility of excessive transmission continuation, abnormality
of the cooling fan action, or an abnormality in the TX block circuit.
Proceed the general circuit troubleshooting.
The temperature of HPA (High Power Amp) is abnormal (too high).
(HPA) Error
There may be a possibility of excessive transmission continuation, abnormality
of the cooling fan action, or an abnormality in the TX block circuit.
Proceed the general circuit troubleshooting.
IF IC Error
The calibration of IF IC is failed.
Contact to our service center for further assistance.
Assumed Condition / Measures

Advertisement

Table of Contents
loading

Table of Contents