Kenwood NXR-1800 Service Manual page 70

Uhf repeater
Hide thumbs Also See for NXR-1800:
Table of Contents

Advertisement

Item
PC tuning mode
18.
1)Adj item:
Courtesy
[Courtesy Tone Deviation
Tone
(Analog Narrow)]
Deviation
[Courtesy Tone Deviation
(Analog)
(Analog Wide 5k)]
[Courtesy Tone Deviation
(Analog Wide 4k)] (E2 type
only)
2) Adj item:
[L1], [L3], [L5], [C1], [C3], [C5],
[H2], [H4], [H6], [OL]
Deviation meter
LPF: 15kHz
HPF: OFF
19. CW
1)Adj item:
ID
[CW ID Deviation (Analog
Deviation
Narrow)]
(Analog)
[CW ID Deviation (Analog Wide
5k)]
[CW ID Deviation (Analog Wide
4k)] (E2 type only)
2) Adj item:
[L1], [L3], [L5], [C1], [C3], [C5],
[H2], [H4], [H6], [OL]
Deviation meter
LPF: 15kHz
HPF: OFF
1-70 (No.RA094<Rev.002>)
Measurement
Test-
Termi
Unit
Unit Parts
equipment
nal
Deviation
TX
meter
ANT
Oscilloscope
Deviation
TX
meter
ANT
Oscilloscope
Adjustment
Method
PC
Write Reference value for
ADJ
each adjustment point as
follows.
Reference Value:
[Analog Narrow]
[L1], [L3], [L5], [C1], [C3],
[C5], [H2], [H4], [H6], [OL]
164(E), 165(E2)
[Analog Wide 5k]
[L1], [L3], [L5], [C1], [C3],
[C5], [H2], [H4], [H6], [OL]
171(E), 172(E2)
[Analog Wide 4k]
[L1], [L3], [L5], [C1], [C3],
[C5], [H2], [H4], [H6], [OL]
176(E2)
Transmit at each
adjustment point and
check that the deviation
is within the specified
range.
PC
Write Reference value for
ADJ
each adjustment point as
follows.
Reference Value:
[Analog Narrow]
[L1], [L3], [L5], [C1], [C3],
[C5], [H2], [H4], [H6], [OL]
459(E), 461(E2)
[Analog Wide 5k]
[L1], [L3], [L5], [C1], [C3],
[C5], [H2], [H4], [H6], [OL]
474(E), 477(E2)
[Analog Wide 4k]
[L1], [L3], [L5], [C1], [C3],
[C5], [H2], [H4], [H6], [OL]
488(E2)
Transmit at each
adjustment point and
check that the deviation
is within the specified
range.
Specifications/
Remarks
[Analog Narrow]
500Hz±50Hz
[Analog Wide 5k]
1000Hz±50Hz
[Analog Wide 4k]
800Hz±50Hz
Press [Apply All]
button to store the
adjustment values
after all adjustment
points have been
adjusted.
[Analog Narrow]
1000Hz±50Hz
[Analog Wide 5k]
2000Hz±50Hz
[Analog Wide 4k]
1600Hz±50Hz
Press [Apply All]
button to store the
adjustment values
after all adjustment
points have been
adjusted.

Advertisement