Kenwood NXR-1800 Service Manual page 61

Uhf repeater
Hide thumbs Also See for NXR-1800:
Table of Contents

Advertisement

Item
PC tuning mode
6. Low RF
1) Test Channel: Channel 1
Power
Down
2) Adj item:
Detection
[Low RF Power Down
Detection]
3) Press [Transmit] button.
7. Ramp
1) Test Channel: Channel 1
Offset
2) Adj item: [Ramp Offset]
8.
1) Adj item: [Balance]
Balance
2) Adj item:
[L1], [L3], [L5], [C1], [C3], [C5],
[H2], [H4], [H6], [OL]
Deviation meter
LPF: 3kHz
HPF: OFF
3) Press [Transmit] button.
Measurement
Test-
Termi
Unit
Unit Parts
equipment
nal
Power
TX
meter
ANT
Ammeter
Deviation
TX
meter
ANT
Oscilloscope
Adjustment
Method
PC
Change the adjustment
ADJ
value to become 0.3W
within the specified
range.
PC
Write the Fixed value as
ADJ
follows.
228(E), 228(E2)
PC
The Deviation of 20Hz
ADJ
tone frequency is fixed
approx. at 2.5kHz.
Change the adjustment
value of 2kHz tone to
become the same
deviation of 20Hz tone
(approx. 2.5kHz) within
the specified range.
While transmitting, click
the check box "2kHz Sine
Wave" to change the
tone between 20Hz and
2kHz.
(No.RA094<Rev.002>)1-61
Specifications/
Remarks
0.3W±0.1W
Press [Apply] button
to store the
adjustment value.
Note:
Power spec is the
factory adjustment
condition.
Within ±15Hz
difference to the
deviation of 20Hz
tone.
Press [Apply All]
button to store the
adjustment values
after all adjustment
points have been
adjusted.

Advertisement

Table of Contents
loading

Table of Contents