Intuis Edel 200 AIR D/2 Installation Manual

Intuis Edel 200 AIR D/2 Installation Manual

Domestic hot water heat pump
Table of Contents

Advertisement

Quick Links

Edel
Domestic hot water heat pump
using exterior or non-heated ambient air
Installation manual
Manual ref. : 1898866
Edition n° 24.06
* Concerns Edel 353420, 353430, 353431, 353703, 353704 models.
AIR
Edel 200 AIR D/2
Ref. 353420
Edel 270 AIR D/2
Ref. 353430
Edel 270 AIR DE/2
Ref. 353431
Edel 200 AIR C/2
Ref. 353703
Edel 270 AIR C/2
Ref. 353704
Made in
France

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Edel 200 AIR D/2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Intuis Edel 200 AIR D/2

  • Page 1 Edel Domestic hot water heat pump using exterior or non-heated ambient air Edel 200 AIR D/2 Installation manual Ref. 353420 Edel 270 AIR D/2 Ref. 353430 Edel 270 AIR DE/2 Ref. 353431 Edel 200 AIR C/2 Ref. 353703 Edel 270 AIR C/2 Ref.
  • Page 2 DOMESTIC HOT WATER HEAT PUMP 200 -270L AIR D/2 - INSTALLER MANUAL...
  • Page 3: Table Of Contents

    CONTENTS 1 - SAFETY ............4 6.10 - Installer menu ...................23 6.10.1 - PV mode ........................23 2- RECOMMENDATIONS ........6 6.10.2 - Adjusting the operating settings ..............23 ANTI-BACT 2.1 - Storage ....................6 6.10.2.1 - Anti-legionellosis cycle ........24 fan mode ..............24 6.10.2.2 - 2.2 - Transport ....................6 T°C.
  • Page 4: Safety

    Preserving these documents Danger resulting from improper use • This manual and all other relevant documents should be given to Any work carried out by an unqualifi ed person the system user. can result in damage to the installation or in The system user should keep these manuals for future reference.
  • Page 5 A method of disconnection ensuring a Maintenance - Troubleshooting complete cut-off according to Category • Drainage : Turn off the power supply and the III conditions must be installed in the fi xed cold water, open the hot water valves and then piping to conform to installation regulations.
  • Page 6: 2- Recommendations

    2- RECOMMENDATIONS 2.1 - Storage STORAGE PRECAUTIONS: The appliance can only function when • Admissible storage and transport filled with water. Never turn on the temperatures of the domestic hot appliance if the tank has not been properly filled water heat pump are from -5°C to +35°C. with water and completely purged of air.
  • Page 7: Handling

    2.3 - Handling 2.5 - Unpacking The appliance is supplied with a transport bag, to facilitate handling • Remove cardboard packaging. to the installation site. • Remove the centring cardboard. • Remove the bag of accessories and the transport bag. •...
  • Page 8: Operating Principle

    3 - OPERATING PRINCIPLE 4 - PRESENTATION The domestic hot water heat pump is a small-capacity heat pump 4.1 - Dimensions dedicated to the production of domestic hot water. The appliance uses the air for the capture of calories and then the bonuses to the water of the tank.
  • Page 9: Technical Specifi Cations And Performances

    4.2 - Technical specifi cations and performances Edel 200 AIR D/2 Edel 270 AIR D/2 Edel 270 AIR DE/2 Edel 200 AIR C/2 Edel 270 AIR C/2 Heat pump performance Nominal volume Max.input power (HP*+back-up) 1900 1900 1900 1900 1900 Air temperature range -7 à...
  • Page 10: Installation

    • The fl oor must be able to support the weight of the domestic hot 5 - INSTALLATION water heat pump (weight of the domestic hot water heat pump fi lled with water 200 L/ 270 L= 260 kg / 335 kg). 5.1 - Placement and positioning The vertical position of the domestic hot water heat pump must be strictly...
  • Page 11: Air Connection

    It is recommended to maintain a distance of 300mm around the 5.2 - Air connection terminals (see diagram below). 5.2.1 - Without piping If installed without piping, the appliance must be installed in non- heated premises (of at least 20m and away from neighboring heated rooms.
  • Page 12: Hydraulic Connections

    5.3 - Hydraulic connections • A new pressure-relief valve (not included) must be installed and set to 6 bars on the domestic cold water supply of the appliance. We would recommend a membrane valve. The membrane valve system must conform to national and domestic standards and regulations in eff ect. never be •...
  • Page 13 1. Stop valve A. Domestic Hot Water (DHW) 2. Pressure reducing valve B. Domestic Cold Water (DCW) Condensate drainage hose 3. Check- valve 4. Dielectric fi ttings (supplied) 5. Pressure relief membrane valve 7. Run-off siphon 8. Domestic water expansion vessel 9.
  • Page 14: Condensates Drainage

    5.4 - Condensates drainage The cooling of the air circulating in the evaporator can lead to the formation of condensate, the quantity of which varies according to the level of humidity in the air. Condensate must be evacuated via a drain pipe at the rear of the appliance to a waste water drain. To ensure correct drainage, the following points must be observed: •...
  • Page 15: Electrical Connections

    5.5 - Electrical connections 5.5.1 - External control Only an external «dry contact», voltage- Do not connect the Domestic hot water free connection is authorised. Otherwise, heat pump to a power line that has been there is a risk of damage to the electronic previously used for a boiler with an automatic circuit board.
  • Page 16: Controlled Ventilation

    5.5.2.2 - Controlled ventilation 5.5.2.3 - Electricity provider contact The domestic hot water heat pump can be used to continuously To prevent the electrical back-up from running during peak hours, ventilate a room even if the heating cycle is complete. connect the dry contact originating from the electricity counter, To stop the fan from operating, connect a timer on a moisture sensor.
  • Page 17: Back-Up Boiler Connection For Models With Heat Exchanger

    5.5.2.5 - Back-up boiler connection for models with heat exchanger --> Switch off the appliance To access the electrical connections: • Remove the cover and the shell of the appliance. • Remove the cover by removing the screws fi xing it to the shell near the lower belt of the shell. •...
  • Page 18: Changing The Fan Speed (Model With Heat Exchanger Only)

    5.5.2.6 - Changing the fan speed (model with heat exchanger only) If the domestic hot water heat pump is connected using pipes, it is necessary to adjust the fan speed to allow for the heat pump to SPEED 1 overcome heat losses caused because of the air connections. SPEED 2 Changing of the fan speed can be done using the electrical terminal of the appliance.
  • Page 19: Set-Up And Use

    6 - SET-UP AND USE 6.1 - Control panel Deterioration risk: it is imperative to fi ll the tank with water before switching on the appliance or connecting it to the electrical supply. • Leave the appliance unplugged. • Open the hot water valve located at the highest point of the Pictograms: installation.
  • Page 20: Setting The Time And Date

    6.4 - Setting the desired water 6.3 - Setting the time and date temperature • Press «Clock settings» 6.4.1 - PV mode inactive 2 6 /09/ 11 The water temperature is adjustable from 30°C to 65°C. Up to 60°C, 1 7: 32 the water is heated using only the heat pump.
  • Page 21: Pv Mode Active

    6.4.2 - PV mode active 6.5 - Holiday/temporary standby mode When PV mode is activated, the water temperature can be set to h o li d a y « » mode puts the appliance on standby while the frost a higher level to favour operation during periods of photovoltaic protection mode remains active.
  • Page 22: Back-Up Type

    6.8 - Back-up type BACK U P • Press the thumbwheel to change the back-up a p pt . ELEC . • Turn the thumbwheel to change the back-up A P PT . CHA UD. • Press the thumbwheel to confi rm Note : The symbol...
  • Page 23: Installer Menu

    7. Turn the dial to select the primary function: 6.10 - Installer menu - Menu → INST. MENU → MODE PV → PRIORITY • Yes: the signals from connectors 1 and 2 take precedence over It may be necessary to adjust certain temperature settings to eco and frost protection modes.
  • Page 24: Anti-Bact

    ANTI-BACT T°C. MINI 6.10.2.1 - Anti-legionellosis cycle 6.10.2.3 - Minimum temperature anti bact The electrical back-up can be activated at the same time as the Factory setting - water temp. 60 C heat pump to prevent the water temperature from going below a Factory setting - minimum comfort level of 38 C.
  • Page 25: Locking The Keyboard

    6.10.3 -Locking the keyboard 6.10.4 - Resetting parameters Permanent and automatic locking Resetting the parameters allows you to go back to the default settings. The «locking» menu enables you to create three possible levels of Go to the «Installer», menu and turn the dial to «Reset PAR.». locking for accessing the menus.
  • Page 26: Maintenance And Troubleshooting

    7 - MAINTENANCE AND .../... → In case of operating on the refrigerant TROUBLESHOOTING circuit: 1) Secure the area you will be working in In order to maintain effi ciency and improve durability it 2) Inform people of the potential danger involved is advised that an annual maintenance check be carried out by a qualifi ed professional.
  • Page 27: Drainage

    • The following procedure must be followed : - Remove the refrigerant ; Neglecting to clean the circuit board and - Purge the circuit with inert gas ; other electronic components in a dusty environment can lead to a risk of overheating - Evacuate to the atmosphere;...
  • Page 28: Recovery

    d) Perform a «pump down» on the appliance where possible. 7.6.6 - Recycling and Disposal e) If it is not possible to vacuum, make a manifold so that the • The product must be labelled indicating that it has been taken out refrigerant can be removed from various parts of the system.
  • Page 29: Troubleshooting

    7.7 - Troubleshooting 7.8 - Sensor data All 4 sensors have the same ohmic values. • No hot water Résistance Check that: (kOhms) • The volume of water consumed is not higher than the volume in the tank. • The time period that the appliance operates is not too short (12h minimum if connected to piping).
  • Page 30: List Of Spare Parts

    7.9 - List of spare parts Edel 200-270 AIR D-DE Edel 200-270 AIR C Nota : availability of spare parts : The spare parts of our products are kept available for 10 years, from the date of stop of mass production, except events beyond our control.
  • Page 31 Edel 200 AIR D/2 Edel 270 AIR D/2 Edel 270 AIR DE/2 Edel 200 AIR C/2 Edel 270 AIR C/2 Description Regulation / display B1244096 B1244096 B1244096 B1244096 B1244096 C3S electronic circuit board controller B4992570 B4992570 B4994474 B4992570 B4992570 Programmed display...
  • Page 32: Error Message Codes: Errors, Solutions And Operating In Case Of Error

    7.10 - Error message codes: errors, solutions and operating in case of error N.B. : Errors can be dismissed by briefl y pressing the dial (manual reset) Temporary operation measures Display Error Probable causes Solutions while waiting for the problem to be solved •Voltage too high on electrical network...
  • Page 33 Temporary operation measures Display Error Probable causes Solutions while waiting for the problem to be solved •The air and defrosting sensors are inverted on the electronics board •The defrosting and water sensors are inverted on the electronics board •Reposition temperature •Incorrect temperature sensor •The defrosting...
  • Page 34: Warranty

    8 - WARRANTY 8.1.2.3 - Installation site Cases (not limited to) where the warranty is void: • Placing the appliance where it can be subject to frost or other The tank is guaranteed against breakage for a period of fi ve (5) years, adverse weather conditions.
  • Page 35: Appendices

    9 - APPENDICES 9.1 - Performance statictics 9.1.1 - COP development 9.1.2 - Heating time The performances are measured during a standardised heating cycle This graph represents the heating time for a full tank depending on with cold water at 10°C. the air and domestic hot water temperatures using the heat pump This graph represents the development of the COP depending on and without a back-up.
  • Page 36: Electrical Wiring Diagram

    9.2 - Electrical wiring diagram 9.2.1 - Edel AIR 200/270 D/2 HP - High pressure - pressure switch CP - 15μF Compressor start-up capacitor C2 - 2μF fan capacitor C5.5 - 5.5μF fan capacitor SV - Defrosting valve RE - 1200W electrical resistance UTL - Electrical back-up temperature limiting safety thermostat AqL - Electrical back-up safety aquastat...
  • Page 37: Edel Air 270 De/2

    9.2.2 - Edel AIR 270 DE/2 HP - High pressure - pressure switch CP - 15μF Compressor start-up capacitor C2 - 2μF fan capacitor C5.5 - 5.5μF fan capacitor SV - Defrosting valve RE - 1200W electrical resistance UTL - Electrical back-up temperature limiting safety thermostat brown AqL - Electrical back-up safety aquastat...
  • Page 38: Edel Air 200/270 C/2

    9.2.3 - Edel AIR 200/270 C/2 HP - High pressure - pressure switch CP - 15μF Compressor start-up capacitor SV - Defrosting valve RE - 1200W electrical resistance UTL - Electrical back-up temperature limiting safety thermostat AqL - Electrical back-up safety aquastat HPS - High pressure - pressure switch brown Compressor...
  • Page 39 NOTES DOMESTIC HOT WATER HEAT PUMP 200 -270L AIR D/2 - INSTALLER MANUAL...
  • Page 40 • Switch off the domestic hot water heat pump before opening it. • Wait for the fan to come to a complete stop before undertaking any work on the appliance. www.intuis.fr Industrial and development site Rue de la République CS 40029 80210 Feuquières-en-Vimeu...