HECKING
Your dryer must be properly installed and vented to achieve maximum drying efficiency and
shorten drying times. Use the minimum recommended installation clearances (found in your
Installation Instructions) to avoid blocking the flow of combustion and ventilation air. Install your
dryer in a well-ventilated room where the temperature is always above 7°C (45°F). Also make sure
that your dryer is leveled. Refer to your Installation Instructions for more information.
V
ENTING
wWARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can
result in death or fire.
If the dryer is not properly installed and vented, it
will not be covered under the warranty.
NOTE: Service calls caused by improper venting
will be paid for by the customer, whether it was a
paid installation or self-installed. For paid installa-
tion, call the company that installed the vent for
adjustment.
1.
Do not use plastic vent or flexible metal foil vent.
10.16cm
(4")
length requirements of vent.
V
OUR
ENT
Use 10.16 cm (4 inch)
heavy metal or flexible
metal vent. Do not kink
or crush flexible metal
vent. It must be com-
pletely extended to
allow adequate exhaust
air to flow. Check vent
after installation. Refer
to your Installation
Instructions for proper
2.
Use a 10.16 cm (4 inch) exhaust hood. Smaller
10.16cm
(4")
10.16cm
(4")
3.
The exhaust vent can be routed up, down, left,
hoods increase drying
times.
right, or straight out the
back of the dryer. Space
requirements are listed
in your Installation
Instructions.
continued on next page