AXIS M11 Series
Specifications
Digital Input
Digital Output
Example
1
DC ground
2
DC output 12 V, max 25 mA
3
Digital input
4
Digital output
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate.
4
Internally connected to pin 1 (DC ground) when active,
and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with
the load, to protect against voltage transients.
46
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA