Planning Information
Integrated Model 700TF( I )
CABINETS
25
(635)
27
(686)
TOP VIEW
Installation without side panels.
2
C
CABINETS
25
(635)
2
27
(686)
5
MINIMUM
/
" (16) SIDE PANELS
8
Installation with side panels.
25
(635)
54
T
(1372)
TOP VIEW
Installation of two units side by side.
C
CABINETS
2
M
27
(686)
5
MINIMUM
/
" (16) SIDE PANELS
8
Installation at end of run.
Dimensions in parentheses are in
millimeters unless otherwise specified.
I N S T A L L A T I O N O P T I O N S
The illustrations on this page show some typical
installations and their dimension considerations.
The depth dimension in the illustrations may vary
depending on cabinet styles, treatment of counter-
tops or other design options.
IMPORTANT NOTE: The depth of each Integrated
unit is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the unit
back, or cabinets forward to achieve a flush fit. This
will require a minimum rough opening depth of 25"
(635). Refer to the illustrations.
D U A L I N S T A L L A T I O N S
If two or more Integrated models are installed side
by side where there is 2" (51) or less of space
between the units, a heater kit is recommended—
TTDUAL for two tall units installed side by side and
BBDUAL for a tall unit and a drawer unit installed
CABINETS
side by side. These optional components are avail-
able through your Sub-Zero dealer. To obtain local
dealer information, visit the Locator section of our
website, subzero.com.
25
(635)