Appendix A - Default Settings; Communications; Serial Port - Honeywell PC45 Series User Manual

Table of Contents

Advertisement

APPENDIX
A
DEFAULT SETTINGS
Use this appendix to view the printer's factory default settings.

Communications

Serial Port

The printer must be connected to the PC through a serial port to view the settings:
From the printer Main Menu, select Settings > Communications > Serial >
COM1.
From the printer web page, click Configure > Communications > Serial.
Serial Port
Setting
Baud Rate
Data Bits
Parity
Stop Bits
Hardware
ENQ/ACK
XON/XOFF To
XON/XOFF From
New Line Character
PC45 Series Printer User Guide
Description
Transmission speed in bits per second (bps) for the serial
port.
Number of bits that define a character or byte.
Specifies how the printer checks the integrity of the
transmitted data.
Number of bits sent at the end of every character to allow the
receiving signal hardware to detect the end of a character
and to resynchronize with the character stream.
Specifies if hardware flow control (RTS/CTS) is used to
manage the rate of data transmission between the device
and the host.
Specifies if software flow control (ENQ/ACK) is used to
manage the rate of data transmission between the device
and the host.
Specifies if software flow control (XON/XOFF) is used to
manage the rate of data transmission to the host.
Specifies if software flow control (XON/XOFF) is used to
manage the rate of data transmission from the host.
Defines the characters that the printer echoes to the host to
indicate that it has moved to a new line.
Default
115200
8
None
1
Disable
Disable
Disable
Disable
CR/LF
81