Wolf Sub-Zero ICBIG15/S Design Manual page 5

Wolf sub-zero icbig15/s: user guide
Hide thumbs Also See for Sub-Zero ICBIG15/S:
Table of Contents

Advertisement

B U I L T - I N O V E N S
P L A N N I N G I N F O R M A T I O N
There are only three different sizes to consider
when planning for your layout. You can choose
either a 762 mm or 914 mm built-in single oven
or a 762 mm double oven.
For ease of installation, Wolf recommends using
838 mm wide cabinets with 762 mm ovens and
991 mm wide cabinets with the 914 mm oven.
You will need a minimum 610 mm of usable
cabinet depth. The cabinet must be able to
support 113 kg for a single oven and 181 kg for
a double oven.
Wolf built-in ovens have a face trim on all four
sides and will overlap stiles and rails. The trim
overlaps 3 mm on the bottom, 5 mm on the top
and 19 mm on each side.
Specifications on the following pages provide
overall dimensions, rough openings and installa-
tion specifics for the three different oven sizes.
We have minimized the information contained
in the illustrations, concentrating on the critical
information you need to plan your installation.
A Wolf single oven may be installed below an
electric or gas cooktop. Wolf built-in ovens are
designed and agency approved for installation
with Wolf cooktops only. Refer to the electric
and gas cooktops sections for additional
specifications. A built-in oven cannot be installed
below a Wolf rangetop.
M O D E L O P T I O N S
Built-In Ovens
762 mm Single Oven – Unframed
Classic Stainless
ISO30U/S
914 mm Single Oven – Unframed
Classic Stainless
ISO36U/S
762 mm Double Oven – Unframed
Classic Stainless
IDO30U/S
E L E C T R I C A L R E Q U I R E M E N T S
International (I) models come with a factory
installed transformer and require a 220-240
V AC, 50/60 Hz electrical supply, fused at the
correct rating for the unit. The appropriate elec-
trical connection must be provided in accordance
with local requirements.
IMPORTANT NOTE: Unless you are using
cabinets deeper than 610 mm, it is recom-
mended that the electrical supply be placed in an
adjacent cabinet within reach of the conduit. A
51 mm diameter hole to route the conduit
through cabinetry will be required. Refer to the
Installation Specifications illustrations on the
following pages for location of the electrical
supply.
You must follow all local codes and ordinances
when installing your service.
This appliance must be installed in accordance with
local codes. The correct voltage, frequency and
amperage must be supplied to the appliance from a
dedicated, grounded circuit that is protected by a
properly sized circuit breaker or time delay fuse.
The proper voltage, frequency and amperage ratings
are listed on the product rating plate.
A C C E S S O R I E S
Built-In Ovens
Bake stone accessory, includes
stone, rack and peel
Additional oven racks
Two-piece broiler pan and
temperature probe
Dehydration racks with door
stop
Accessories are available through
your Wolf dealer.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents