Wolf Sub-Zero ICBIG15/S Design Manual page 42

Wolf sub-zero icbig15/s: user guide
Hide thumbs Also See for Sub-Zero ICBIG15/S:
Table of Contents

Advertisement

P L A N N I N G I N F O R M A T I O N
Wolf sealed burner rangetops come in 762 mm,
914 mm and 1219 mm widths. Specifications on
the following pages provide overall dimensions,
finished rough opening dimensions and installa-
tion specifics for each size of sealed burner
rangetop. We have minimized the information
contained in the illustrations, concentrating on
the critical information you need to plan your
installation.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf
sealed burner rangetop to avoid fires or damage
to adjacent cabinetry or kitchen equipment.
Please follow the minimum clearances estab-
lished in the finished rough opening dimensions.
Refer to specifications on the following pages
for your model.
A downdraft can be used with Model
ICBSRT304. An accessory trim kit is necessary
for this installation. Contact your Wolf dealer for
details.
B U R N E R R A T I N G
Sealed Burner Rangetops
Surface Burners
Infrared Charbroiler
Natural Gas
LP Gas
Infrared Griddle
Natural Gas
LP Gas
French Top
Refer to the specific model requirements
for risers in non-island installations.
42
5.0 kW with .3 kW
delivered at simmer
(1) 3.2 kW with .1 kW
delivered at simmer
6.2 kW
5.4 kW
5.5 kW
5.5 kW
5.0 kW
W O L F S E A L E D B U R N E R R A N G E T O P S
E L E C T R I C A L | G A S R E Q U I R E M E N T S
Specifications on the following pages provide
electrical and gas requirements for each size
of sealed burner rangetop.
The Wolf sealed burner rangetop is CB approved
and manufactured for a 220-240 V AC, 50/60 Hz
electrical supply to operate the electronic ignition
system. The service should have its own 15 amp
circuit breaker.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Wolf sealed burner rangetops are designed to
operate without a regulator on natural gas at
17-25 mb pressure or LP (propane) gas at 25-45
mb.
If local codes permit, a certified, .9 m long,
13 mm or 19 mm I.D. flexible metal appliance
connector is recommended for connecting the
rangetop to the gas supply line.
The platform for the rangetop must be 19 mm
thick and include a cut-out at the right rear for
gas supply and electrical connections.
Locate electrical and gas supply within the
shaded area shown in the Installation Specifica-
tions illustration for your model.
You must follow all local codes and ordinances
when installing your services.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents