Grounding & Plug Requirements
This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.
For 110V operation: The plug specified under
"Circuit Requirements for 110V" on the previ-
ous page has a grounding prong that must be
attached to the equipment-grounding wire inside
the included power cord. The plug must only be
inserted into a matching receptacle (see below)
that is properly installed and grounded in accor-
dance with all local codes and ordinances.
L5-30 GROUNDED
LOCKING
RECEPTACLE
Neutral
L5-30
LOCKING
PLUG
Hot
Grounding Prong
is Hooked
figure 2. typical l5-30 plug and receptacle.
For 220V operation: The plug specified under
"Circuit Requirements for 220V" on the previous
page has a grounding prong that must be attached
to the equipment-grounding wire on the included
power cord. The plug must only be inserted into
a matching receptacle (see following figure) that
is properly installed and grounded in accordance
with all local codes and ordinances.
GROUNDED
6-15 RECEPTACLE
Current Carrying Prongs
6-15 PLUG
Grounding Prong
figure 3. typical 6-15 plug and receptacle.
-10-
Improper connection of the equipment-grounding
wire can result in a risk of electric shock. The
wire with green insulation (with or without yellow
stripes) is the equipment-grounding wire. If repair
or replacement of the power cord or plug is nec-
essary, do not connect the equipment-grounding
wire to a live (current carrying) terminal.
Check with a qualified electrician or service per-
sonnel if you do not understand these grounding
requirements, or if you are in doubt about whether
the tool is properly grounded. If you ever notice
that a cord or plug is damaged or worn, discon-
nect it from power, and immediately replace it with
a new one.

Extension Cords

We do not recommend using an extension cord
with this machine. If you must use an extension
cord, only use it if absolutely necessary and only
on a temporary basis.
Extension cords cause voltage drop, which may
damage electrical components and shorten motor
life. Voltage drop increases as the extension cord
size gets longer and the gauge size gets smaller
(higher gauge numbers indicate smaller sizes).
Any extension cord used with this machine must
contain a ground wire, match the required plug
and receptacle, and meet the following require-
ments:
Minimum Gauge Size (110v) ................12 aWG
Minimum Gauge Size (220v) ...............14 aWG
Maximum Length (Shorter is better).......50 ft.
Model g0443 (Mfg. since 11/09)