General cleaning, Maintenance, and Lubrication
1. BeFOre eacH uSe, inspect the general
condition of the tool. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts,
• damaged electrical wiring, and
• any other condition that may
affect its safe operation.
troubleshooting
problem
Motor shuts off
1. Motor may have been shut off
during use.
2. GFCI breaker tripped.
Cable kinks, twists,
1. Too much force on cable.
or breaks.
2. Too much slack between
3. Cable used is wrong
4. Cable exposed to acid.
5. Cable worn out.
Cable tangles in drum. 1. Too much force on cable.
2. Motor running in reverse.
3. Distributor tube frozen.
Power Cord GFCI
1. Motor Direction Switch defective.
trips when unit is
2. Frayed Power Cord.
plugged in or when
3. Short circuit in Motor.
Foot Pedal is pressed.
4. Excess moisture touching Power
5. Faulty GFCI unit.
Motor does not
Pneumatic Foot Pedal may have a leak.
operate or Foot
Pedal sticks.
"Forward/Reverse"
Centrifugal switch requires motor to
Switch does not work.
come to a complete stop before it will
allow direction of motor to be changed.
Item 59533 59534
probable cause(s)
by its internal thermal protection
switch, or auto reset breaker.
Drain Cleaner and drainpipe inlet.
size for drain pipe.
Cord or Drain Cleaner.
For technical questions, please call 1-888-866-5797.
2. aFter uSe, wipe external surfaces
of the tool with clean cloth.
3.
WarninG! tO preVent SeriOuS
inJury: if the supply cord of this power
tool is damaged, it must be replaced only
by a qualified service technician.
Solution(s)
1. Turn motor off. Allow motor to cool off
completely before restarting and stay clear
of cable when turning motor back on.
2. Make sure all electrical components
are dry and all insulation is in good
repair. Press reset button. If GFCI
trips again, have machine serviced by
qualified electrician before further use.
1. Do not force cable. Let cutter do the work.
2. Move Drain Cleaner to within
two feet of drainpipe inlet.
3. Change cable size.
4. Clean and oil cable regularly.
5. Replace cable.
1. Do not force cable. Let cutter tool do the work.
2. Retract Cable with Motor Direction
Switch in Forward position.
3. Technician should lubricate
distributor tube bearings.
1. Repair or replace Motor Direction Switch.
2. Repair or replace Power Cord.
3. Have Motor repaired by a qualified
technician; Replace Motor.
4. Dry cord and unit.
5. Electrician must Replace Power Cord with GFCI.
Check for leaks in air line leading from
Foot Pedal. Check for tears and holes
in Foot Pedal. Replace if needed.
Move "Forward/Reverse" Switch to "Off" position
and allow motor to stop before changing from
"Forward" to "Reverse" or vice versa.