Dmx-512 Addressing With Id Address - Iridium Arc Bar Pro 1215 Manual

Ip65 12x15w rgbw led
Table of Contents

Advertisement

DMX-512 addressing with ID address

1. Follow instructions 1 for DMX 512 addressing.
2. Activate ID addressing in each fixture by setting panel function "ID ON/OFF" to ON.
"Settings" to "ID ON/OFF" to "ON" For every DMX 512 starting address the user can set 66
separate ID addresses. Set ID addresses in each fixture by setting panel function " ID
address" to incremental values.(l.e. 1, 12, 24, 36 etc...) "Settings" to "address" to "01~66".
DMX address: 001 DMX address: 001 DMX address: 001 DMX address: 012 DMX address: 012 DMX address: 012
ID address: 01
UPLOAD
Master
Slave
First,set one light, which involves the program you have edited in EDIT menu
and want to upload, in Master mode,and others in Slave mode.
Then,connect all the lights with DMX cables.Finally,select the UPLOAD
menu of the Master light and press ENTER.All the programs edited in the
Master light will be uploaded to the Slave lights.
ID address: 02
ID address: 03
The figure above shows a simple DMX layout which has used three units at each DMX address. The
three units have different ID addresses which allows the user to collectively control the whole group of
units at that DMX address by setting Channel 10 to 0, or to control each unit independently by first
selecting the DMX address and then by using Channel 11 to locate the target ID address. (Note that
when using ID addresses it is also possible to activate ADAS which allows for even more option with
DMX addressing and control.
Slave
Slave
ID address: 01
ID address: 02
Slave
Slave
17
ID address: 03

Advertisement

Table of Contents
loading

This manual is also suitable for:

113531

Table of Contents