Lennox BCE3M E Series Installation Instructions Manual page 14

Table of Contents

Advertisement

The power supply must be sized and protected
according to the specifications supplied on the product.
This air handler is factory-configured for 240 volt,
single phase, 60 cycles. For 208-volt applications, see
"208 Volt Conversion" later in this section.
Separate openings have been provided for 24V low
voltage and line voltage. Refer to the dimension
illustration for specific location.
This unit is provided with holes for conduit. Use
provided caps to seal holes not used.
Typical unit wiring (as well as wiring of optional field-
installed electric heat) is given in figure 18. Refer to
the instructions provided with the electric heat section
for proper installation.
For optional field-installed electric heat applications,
refer to the instructions provided with the accessory
for proper installation.
WARNING
USE COPPER CONDUCTORS ONLY!
1.
Disconnect all power supplies.
2.
Remove the air handler access panel.
3.
Route the field supply wires to the air handler electrical
connection box.
4.
Use UL-listed wire nuts to connect the field supply
conductors to the unit black and yellow leads, and the
ground wire to ground terminal marked GND.
5.
Replace the air handler access panel.
NOTE: To avoid the possibility of moisture damage to the
control in some right-hand discharge configurations, the
control panel can be relocated to the end panel as shown
in figure 16.
Page 14 of 22
Figure 15
208 Volt Conversion
1.
Disconnect all power supplies.
2.
Remove the air handler access panel.
3.
Using the wiring diagram located on the unit access
panel as a reference, move the 2 connected black
transformer leads from the 240 volt terminal on the
transformer to the 208 volt terminal on the transformer.
Electrically ground air handler. Connect
ground wire to ground terminal marked
"GND".
Failure to do so can result in death or
electrical shock.
208 / 240 VOLT TRANSFORMER
PRIMARY
240 Volts
Issue 1810
Figure 16
WARNING
SECONDARY
208 Volts
Figure 17
507623-02