Start-Up, Adjustment, And Safety Check - Carrier 59TN6C Installation, Start-Up, Operating, Service And Maintenance Instructions

Two-stage, variable-speed, multipoise 35 in. (889 mm) tall, condensing gas furnace
Table of Contents

Advertisement

59TN6C: Installation, Start-up, Operating, Service and Maintenance Instructions
START-UP, ADJUSTMENT, AND SAFETY
CHECK
!
IMPORTANT INSTALLATION AND START-UP
PROCEDURES
Failure to follow this procedure may result in a nuisance smoke or odor
complaint.
The manifold pressure, gas rate by meter clocking, temperature rise and
operation must be checked after installation. Minor smoke and odor
may be present temporarily after start-up from the manufacturing
process. Some occupants are more sensitive to this minor smoke and
odor. It is recommended that doors and windows be open during the
first heat cycle.
CAUTION
!
UNIT OPERATION HAZARD
Failure to follow this caution may result in intermittent unit operation
or performance dissatisfaction.
These furnaces are equipped with a manual reset limit switch in burner
assembly. This switch opens and shuts off power to the gas valve if an
overheat
condition
(flame
assembly/enclosure.
Correct
improper gas pressure setting, improper burner or gas orifice
positioning, or improper venting condition before resetting switch. DO
NOT jumper this switch.
General
1. Maintain 115-V wiring and ground. Improper polarity will result in
rapid flashing control diagnostic light and Status code (10.1) is
displayed. The furnace will NOT operate.
2. Make thermostat wire connections at the 24-V terminal block on
the furnace control. Failure to make proper connections will result
in improper operation.
3. Gas supply pressure to the furnace must be greater than 4.5-in. w.c.
(0.16 psig) but not exceed 14-in. w.c. (0.5 psig).
4. Check all manual-reset switches for continuity.
5. Natural gas service pressure must not exceed 0.5 psig (14- in. w.c.,
350 Pa), but must be no less than 0.16 psig (4.5-in. w.c., 1125 Pa).
Display
Operating Mode
tSt
Test
PUr
Purge
HSi
Hot Surface Igniter
Fn
Fan
End
End Test
Err
Error
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
NOTICE
rollout)
occurs
in
the
inadequate combustion-air
Table 21 – Test Sequence
Function
Confirms start of Component Test mode.
Inducer ON High for 10 seconds before next stage. Inducer remains ON for test duration.
Hot Surface Igniter ON for 15 seconds, then OFF.
Blower ON at 50% torque for 10 seconds, then OFF.
All component OFF except for Inducer ON Low for 10 seconds. Display returns to
is detected or fault condition activates during the test sequence, control will abort and display
seconds.
Displayed if component test is not able start. Check for thermostat inputs or faults, and system status is Idle
iDl
(
).
6. Blower door must be in place to complete 115-V electrical circuit
and supply power to the furnace components.
Start-Up Procedures
1. Purge gas lines after all connections have been made.
2. Check gas lines for leaks.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, or death.
Blower access door switch opens 115-V power to control. No
component operation can occur unless switch is closed. Caution must
be taken. Do not touch uninsulated electrical components when
manually closing this switch. for service purposes.
3. To Begin Component Self-Test
a. Remove thermostat wire connected to R terminal on control to
ensure no thermostat demands are present.
b. Temporarily depress blower door switch to power the control
board to complete component self-test.
SHOCK HAZARD
Failure to follow this caution could result in personal injury.
burner
Do not tape or permanently allow the door switch to be bypassed.
supply,
Temporarily depress the door switch with one hand while accessing the
service buttons with your other hand. Do not touch uninsulated
electrical components.
c. To initiate the component test sequence, the control must be in
(idL) mode. no thermostat demands (W, Y, G). Select component
test (Ct) from menu select buttons to start the component test
sequence. Once initiated the furnace control will perform the test
sequence as shown in
thermostat wire to R terminal on control board and reinstall
blower door.
4. Operate furnace per instruction on door.
5. Verify furnace shut down by lowering thermostat setting below
room temperature.
6. Verify furnace restarts by raising thermostat setting above room
temperature.
54